Back to search

The Ohio State University

Measuring Biomechanical Loads on the spine during Patient Lifting Sling Application and Removal: Assessing the effects of Work Method, Patient Weight and Bed Height

Abstract

dc:description

Objective research is sparse on the biomechanics and ergonomics of the patient sling application and removal processes, which are necessary ancillary tasks that must be performed when using mechanical aids for patient transfer. This repeated measures study quantified the biomechanical loading on the spine as 12 female nurses applied and removed slings under two patients of differing weights (54 and 100 kg), using two work methods, and while working at three bed heights (56, 71, 93 cm). Three-dimensional spine loads at each vertebral level between T12/L1 and L5/S1 were measured using an EMG-assisted biomechanical model. Sling application and removal was performed either with the nurses remaining on one side of the bed for the entire task or by the nurse accessing the patient from both sides of the bed. Shear loading at the L5/S1 level and Lateral Shear loading at the L1/L2 level and above exceeded the tolerance threshold limit for disc failure. With respect to the lighter weight patient, the heavier patient led to significantly higher compression, A/P shear and lateral shear. While mean compressive forces were generally under 3400 N, several participants exceeded this level when applying the sling under the heavier patient. In general, working from both sides of the bed generated slightly higher A/P Shear loading than the one-sided method. Raising the bed decreased compression and A/P shear significantly. Therefore, increasing the bed height to at least the nurse’s knuckle height is recommended based on the findings from this study.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Industrial and Systems Engineering
Grantor dc:publisher
The Ohio State University
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nagavarapu, Shasank
Advisor dc:contributor.advisor
  • Lavender, Steven

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Nagavarapu, Shasank. Measuring Biomechanical Loads on the spine during Patient Lifting Sling Application and Removal: Assessing the effects of Work Method, Patient Weight and Bed Height. masters thesis, The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1440270675