Abstract

dc:description

Total knee replacement (TKR) has been a valid treatment option for end stage joint OA to alleviate pain and restore function of knees that suffer from disease or trauma. TKR affects the kinetics and kinematics of the operated knee. In-vivo and ex-vivo canine TKR kinematic data is currently lacking in dogs. Using a 6-degrees-of-freedom (6-DOF) robotic kinematics system, we tested the hypothesis that TKR would result in statistically significant alterations in stifle kinematics when compared with the intact joint. A joint testing system with 6-DOF (Rotopod R2000) was used to first, cycle the joints through range of motion, second to apply external loads on different stifle flexion angles (135°, 90°, 60°) and lastly to apply gait cycle to 8 cadaveric canine stifles, before and after TKR. Kinematic variables included cranio-caudal translations, internal-external rotations and varus-valgus rotations. A Wilcoxon Rank Sum test was performed. Significance level was set at p< .05.During passive flexion tests, the TKR tibiae moved significantly more caudally than the native tibiae. Significant internal rotation of the TKR tibiae occurred as a result of implantation of the prosthesis. The TKR tibiae had linear internal rotation throughout flexion. Cranio-caudal translation was significantly greater after TKR (p<.01) in 90° and 60°. Internal-external rotation was significantly greater prior to TKR (p< .01) in all flexion angles. Varus-valgus rotation was significantly greater prior to TKR procedure (p<.01) only in 60° of flexion. Stifle joint kinematics are significantly different after TKR. Canine TKR (BioMedtrix) provides semi-constrained technology of the knee. Kinematic data from this ex-vivo study will provide fundamental data to understand and compare in-vivo TKR kinematic.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Comparative and Veterinary Medicine
Grantor dc:publisher
The Ohio State University
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bertran, Judith

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Bertran, Judith. THREE-DIMENSIONAL ROBOTIC KINEMATIC ANALYSIS OF THE CANINE TOTAL KNEE REPLACEMENT. masters thesis, The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1447700134