The Ohio State University
Effect of Scanning Conditions on Cone Beam Computed Tomography Gray Value
Abstract
dc:descriptionCone beam computed tomography (CBCT) produces a three-dimensional image that allows for precise diagnosis and better treatment planning of various dental complications. However, reliability of CBCT to measure bone mineral density (BMD) measurement has not fully evaluated. Thus, the objective of the current study was to examine whether the CBCT can produce the gray value distribution parameters (mean, variability, and 5 percentile low and high) and their magnitudes are influenced by different scanning conditions and scanners. ATOM Max dental and diagnostic artificial head (model 711-HN, CIRS, Norfolk, VA) was scanned by two CBCT scanners (Planmeca ProMax® 3D Mid and iCAT). Planmeca and iCAT scanners used full field of view with normal dose and ultra-low dose (ULD) sub-options for 3 scanning resolutions (200, 400, and 600 micron voxel sizes) and 4 scanning resolutions (200, 250, 300 and 400 micron voxel sizes), respectively. After 9 weeks, the artificial head was scanned again by the Planmeca scanner with the same scanning conditions. In addition, 2 hydroxyapatite phantoms (1220, and 1540 mg/cm3) were adhered on the artificial head and scanned using the normal and ULD scanning conditions of 400 micron voxel size with both scanners. The gray value histograms of each region were utilized to determine mean value (Mean), standard deviation (SD), 5th percentiles low and high (Low5 and High5) of gray values. The gray value parameters were successfully measured by the CBCT images. The different scanning conditions and the bilateral locations of the artificial head did not have significant effects on measurements of the gray value parameters (p>0.436) with excellent repeatability. However, the iCAT scanner produced significantly different gray values from the Planmeca scanner (p<0.001). These results suggested that the CBCT can measure a material density while calibration of absolute measures is necessary to obtain comparable values between different scanners.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Dentistry
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- England, Gregory Miles
- Advisor dc:contributor.advisor
-
- Kim, Do-Gyoon
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1458951153