The Ohio State University
On the Control and Operation of Modular Multilevel Converters at Low Output Frequencies
Abstract
dc:descriptionModular multilevel converters (MMCs) have recently gained remarkable attention in medium-voltage (MV) AC/DC and DC/AC power conversion applications. To use the MMC as a MV variable-speed drive, special control techniques are deployed to mitigate the voltage fluctuations in its floating capacitors. In these control techniques, a common-mode (CM) voltage is injected at a frequency much higher than the output frequency. Furthermore, the internal circulating currents are controlled based on the injected CM voltage and the operating conditions of the load. It is desirable to increase the CM frequency as much as possible to minimize the voltage ripples in the capacitors. However, the performance of the circulating current controller degrades as the frequency is increased, causing significant errors and leading to undesired or even unstable outcomes.At first, this research originally investigates the errors in the circulating currents and how it affects other MMC system variables. The system is analyzed when deviations in the circulating currents are assumed to exist. Mathematically, it is shown that the error creates voltage fluctuations in the MMC capacitors at the output frequency. Furthermore, the amplitudes of these error-dependent voltages increase as the CM frequency goes higher. As a result, an upper limit exists for the CM frequency selection.Secondly, a method is suggested to suppress these output-frequency error-dependent voltages by compensating the circulating current errors. The method requires two additional parameters in the reference circulating current that are chosen by trial-and-error. This method makes it possible to select high CM frequencies while maintaining simple control structures and low switching frequencies.Thirdly, a simpler method to enhance the suppression of capacitor voltage fluctuations is proposed. The method requires only one additional parameter in the circulating current reference instead of two. Besides, a relationship between this additional parameter and the circulating current error is established and verified, and a two-step procedure is presented to apply the proposed method. Simulations and experimental results are given to validate the theoretical analysis presented in this work.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Electrical and Computer Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Al Sabbagh, Muneer
- Advisor dc:contributor.advisor
-
- Xu, Longya
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1573924671856689