The Ohio State University
Development of Chemical Looping Combustion Technology for Energy Production and Sulfur Capture - Experimental Aspect, Process Modeling, Hydrodynamic Studies
Abstract
dc:descriptionCoal-direct chemical looping (CDCL) process developed at Ohio State University (OSU) is a novel carbon capture technology for coal based electricity generation. This process can produce sequestration ready CO2 while generating electricity with minimum energy penalty. To date, this process has been demonstrated successfully from lab-scale to pilot-scale with near 100% carbon capture using various fuels such as metallurgical coke, sub-bituminous and bituminous coals. The work presented in this dissertation primarily aims to determine the fate of sulfur in OSU’s Fe-based CDCL process and also develop a novel process for energy production from coal with in-situ sulfur capture. The fate of sulfur in the coal-direct chemical looping system was investigated in the sub-pilot reactor system. The sulfur balance was successfully closed during the injection of high sulfur coal. More than 69% of the total amount of atomic sulfur in coal was released as SO2 and H2S from the reducer flue gas stream while less than 5% was emitted as SO2 from the combustor spent air. The remaining atomic sulfur was retained in coal ash as inorganic sulfur compounds. The finding suggests an acid gas removal system targeting both H2S and SO2 is required to meet the recommended quality of CO2 stream for sequestration and transportation. Using the determined ratio of SO2 and H2S, a properly designed Claus plant can enable the recovery of elemental sulfur as a value-added byproduct. The combustor spent air was found to comply with the US EPA sulfur emission regulation and can be released to the atmosphere without a costly acid removal system. The relationship between the sulfur and carbon capture efficiencies was established experimentally and was found to be proportional to each other throughout the experiment at a slope of 0.8 below 93% of carbon capture efficiency and near 1 above 93%. This was attributed to the delayed release of organic sulfur during incomplete char gasification in the reducer. The finding affirms the effectiveness of the counter-current moving bed design for minimizing the amount of carbon and sulfur emission in the combustor spent air with an average carbon and sulfur capture efficiency of 96.5 and 95%, respectively. Sulfur deposition on the iron based oxygen carriers did not affect the system performance, and complete removal of deposited sulfur was observed during oxidation in a thermogravimetric analyzer. Compared with chemical looping systems using circulating fluidized bed configuration, the use of a moving bed reducer has the additional benefit of minimizing slippage of char into the combustor due to the use of large oxygen carrier; resulting in lower sulfur emission in the combustor spent air. The findings demonstrate the robustness of the coal-direct chemical looping system to handle high sulfur coal without a complicated acid gas cleaning scheme or severe performance penalties. A novel process scheme for energy production from coal with in-situ sulfur capture, known as the coal-direct chemical looping process with sulfur removal (CDCL-SR), is proposed in this study. The proposed process utilizes multimetal oxide comprising the oxides of copper and calcium supported on inert SiC as the oxygen carrier to combust coal and simultaneously produce separate streams of CO2 and SO2, thus eliminating the need for downstream processing units. The computational software ASPEN Plus has been utilized to carry out detailed reactor simulations along with a thorough thermodynamic analysis of the process. The reactor modeling results indicate that the moving bed reducer can effectively convert all the carbon present in coal into CO2 while capturing sulfur in the form of calcium sulfide in the reduced oxygen carrier. The reduced oxygen carrier can in turn be oxidized using steam to produce pure SO2 stream that can be readily utilized. Process simulation results indicate that the proposed CDCL-SR process has thermal and exergy efficiencies of 86% and 51%, respectively, significantly higher than both the conventional pulverized coal Rankine cycle and Fe-based CDCL processes.The final part of this work focuses on understanding the hydrodynamic characteristics of slugging fluidization regime observed in the combustor reactor of the CDCL process. Slugging represents one of the major regimes in fluidization, which occurs in small diameter beds with large bed height-to-diameter ratio or in large diameter beds with internals that resemble multiple small diameter fluidized beds. Slug types include round-nosed slug, wall slug and square-nosed slug. Studies of the slugs have been mainly focused on round-nosed or wall slugs known as half slug, typically occurring in Geldart Group A particle fluidization. The square-nosed slug typically occurring for Geldart Group D particles appears to be regarded as simple in its structure. The Electrical Capacitance Volume Tomography (ECVT) imaging of the square-nosed slugging phenomena conducted in this study reveals otherwise. That is the structure of the square-nosed slug is, in fact, complex, particularly with respect to its dynamic variation in fluidization. More broadly, this study examines experimentally the hydrodynamic characteristics of the square-nosed fluidization regime. Specifically, simultaneous measurements from multiple ECVT sensors provide non-invasive, continuous, 3-dimensional imaging of the entire flow region of the slugging bed and hence enabling the dynamic characterization of the evolution of the slugs. The analysis of the 3-D images reconstructed for real-time gas-solid volume fraction profile of the slugging fluidized bed indicates that there are three different zones, namely, the bottom fluidization zone, the gas slug zone, and the solid slug zone, co-existing in the bed. The three zones present different hydrodynamic characteristics during the slug evolution. It is found that varying the gas velocity of the slugging bed mainly varies the maximum length of the gas slug zone, while it only has a minor effect on the lengths of the bottom fluidization zone and solid slug zone. It also has an insignificant effect on the solid volume fraction of the three zones.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Chemical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pottimurthy, Yaswanth
- Advisor dc:contributor.advisor
-
- Fan, Liang-Shih
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1637253201651774