The Ohio State University
Biofilm Growth Dynamics Characterized by Electrochemical Impedance Spectroscopy
Abstract
dc:descriptionThe treatment of biofilm-related infections and implant failure is an area of major concern that costs the healthcare industry billions of dollars each year. While a great deal of research has been conducted to eliminate biofilms after an infection has set in, less is known about the underlying causes behind these infections and the way biofilms form. Biofilm growth and communication are only a few of their many characteristics that exhibit electrochemical properties. These characteristics can be measured through electrochemical impedance spectroscopy (EIS).In this thesis, we design and iterate on the fabrication procedure for two versions of an EIS system with flat-patterned silver electrodes capable of collecting electrochemical data from Staphylococcus epidermidis biofilms directly above the electrodes. We verify the functionality of the device by using both a two-electrode system and a four-electrode system to measure the impedance of tryptic soy agar (TSA). The behavior of TSA measured by the two-electrode system included a region with a constant phase angle of -42.0 ± 4.6˚, and a region with a phase of 0˚. The 42.0˚ region corresponds to a constant phase element (CPE), or equivalent circuit component where the ratio of real to imaginary impedance stays constant such that the phase is not purely 0˚ or -90˚. The 0˚ region corresponds to a purely resistive circuit component. The CPE is also similar to a Warburg element, which specifically has a constant phase of exactly 45˚. The response of the TSA measured by the four-electrode device was almost purely resistive with an average phase of -0.7 ± 1.7˚.After verifying that the device could produce repeatable data, the two-electrode system was selected to measure the electrochemical response of S. epidermidis grown on a thin layer of TSA for 0 hours, 8 hours, 16 hours, and 24 hours. All four growth durations showed an increase in the absolute value of the phase angle and the impedance of the system as opposed to TSA-only data. The 0-hour measurements were closest to the TSA-only measurements in phase angle and impedance. The 8-hour measurements had the greatest increase in absolute value of phase angle and impedance, both of which decreased with 16-hour and 24-hour measurements. The results from the biofilm studies were also found to be repeatable.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- The Ohio State University
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kearns, Kaitlyn LeeAnn
- Advisor dc:contributor.advisor
-
- Prakash, Shaurya
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=osu1653301200998967