Back to search

The Ohio State University

Comparison of Techniques for Objective Measurement of Accommodative Amplitude

Abstract

dc:description

SignificanceThis study provides a faster method for objectively measuring accommodative amplitude with an open-field autorefractor and identifies the optimal stimulus locations for eliciting the maximum accommodative response.PurposeObjective measures of accommodative amplitude with an autorefractor take time due to the numerous stimulus demands tested. This study compares three protocols using different amounts and types of demands to shorten the process. This study also aims to determine the optimal accommodative demand or demands that are needed to identify maximum accommodative amplitude in the quickest and most efficient manner.Methods One hundred participants were recruited for four age bins (5-9, 10-14, 15-19, and 20-24 years) and monocular amplitude was measured with an autorefractor using three protocols: 13-demand proximal, 5-demand proximal-lens (letter), and 5-demand proximal-lens (picture). For proximal, measurements were taken as participants viewed a 0.9 mm “E” placed at 13 demands (40 cm to 3.3 cm = 2.5 to 30 D). The other protocols used a target (either the “E” or a detailed picture) placed at 33 and 12.5 cm followed by 12.5 cm with a series of lenses (-2 D, -4 D, and -5.5 D). Accommodative amplitude was defined as the greatest accommodative response measured with each technique. Repeated measures ANOVA was used to compare group mean amplitudes across protocols and one-way ANOVA was used to compare differences between the letter protocols by age bin. Measurements taken at single demands and groups of demands were also analyzed to determine the demand or combination of demands that correctly identified maximum accommodative amplitude.ResultsAmplitudes were significantly different between protocols (P<0.001) with the proximal having higher amplitudes (mean ± SD = 8.04 ± 1.70 D) than both proximal-lens protocols (letter: 7.48 ± 1.42 D, picture: 7.43 ± 1.42 D) by post-hoc Tukey analysis. Differences in amplitude between the proximal and proximal-lens (letter) protocol were different by age group (P=0.003), with the youngest group having larger differences (1.14 ± 1.58 D) than the oldest groups (0.17 ± 0.58 D and 0.29 ± 0.48 D respectively).Variations of demands were analyzed for each age bin to determine the dioptric positions that identified maximum accommodative amplitude. Using measurements taken at demand positions 10.5 and 12 D identified true accommodative amplitude for 80% of 5 to 9 year-olds, 95.8% of 10 to 14 year-olds, 96.2% of 15 to 19 year-olds, and 92% of 20 to 24 year-olds correctly, within 1.0 D of their true maximum. The largest difference from true maximum amplitude was approximately 2 D for 5 to 9 and 10 to 14 year-olds and 1.5 D for 15 to 19 and 20 to 24 year-olds.ConclusionsThe proximal-lens protocols took less time and identified maximum accommodative amplitude in participants age 15 – 24 years; however, they may under-estimate true amplitude in younger children. Utilization of dioptric positions 10.5 and 12 D alone may be a quicker alternative for measurement of accommodative amplitude with good accuracy, given the high percentage of true amplitudes identified with responses from these positions across all age groups.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Vision Science
Grantor dc:publisher
The Ohio State University
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Parks, Sidney Marie
Advisors dc:contributor.advisor
  • Anderson, Heather
  • Kulp, Marjean

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Parks, Sidney Marie. Comparison of Techniques for Objective Measurement of Accommodative Amplitude. masters thesis, The Ohio State University, 2024. http://rave.ohiolink.edu/etdc/view?acc_num=osu171259920118906