Back to search

University of Toledo

Reliability of Lower Extremity Biomechanics During Functional Activity Performance

Abstract

dc:description

Context: Three dimensional, passive motion analysis systems allow researchers to non-invasively, yet thoroughly, examine the biomechanics of patients with many different orthopedic ailments. One problem with this technology is a lack of consistency in the number and placement of retroreflective markers. This results in a difficulty comparing results from studies done in the same lab over time.Objective: The purpose of this study is to determine the reliability of the chosen marker set when using passive motion capture to assess biomechanics during various dynamic tasks.Design: The design is a test-retest study.Setting: Musculoskeletal Health and Movement Science LaboratoryParticipants: Fifteen participants were recruited and volunteered for this study. Fourteen participants (age: 23.9±33.56 years; height: 1.73±0.12 m; mass: 71.93±15.95 kg; body mass index [BMI]: 23.82±2.76 kg/m2) completed the study.Intervention(s): Participants reported to motion analysis laboratory for two trials separated by seven days. The clinician placed 37 retro-reflective markers over the pre-determined anatomical landmarks. The subject then performed self-selected walking gait, standard walking gait, stair ascent/descent, jump landing and sit-to-stand tasks.Main Outcome Measures: The dependent variables include three dimensional, lower extremity biomechanics at the hip, knee, ankle, and trunk during each of the four biomechanics tasks. The independent variable is time (session 1 and session 2). The statistical analysis used to compare the measurements was independent t-tests and intraclass correlations (ICC).Results: Standard gait speed yielded the best ICC values (ICC > 0.652) for kinematics and kinetics at the hip and knee in both the frontal and sagittal plane. All other tasks found varying ICC values for kinetic and kinematic data in the frontal and sagittal plane (0.970 > ICC > 0.003).Conclusion: The present study showed that the chosen marker set is reliable when a novice clinician places the surface markers on the pre-determined anatomical landmarks.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Exercise Science
Grantor dc:publisher
University of Toledo
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alfonsi, Michael
Advisor dc:contributor.advisor
  • Thomas, Abbey

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Alfonsi, Michael. Reliability of Lower Extremity Biomechanics During Functional Activity Performance. masters thesis, University of Toledo, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=toledo1398337862