University of Toledo
Corrosion Detection in Reinforced Concrete Using Acoustic Emission Technique
Abstract
dc:descriptionCorrosion of reinforcing steel is the major cause for deterioration of concrete structures. Corrosion of these steel bars potentially reduces the service life and ductilityof the structures causing early failure of structure, this involves significant cost forinspection and maintenance. Early detection of corrosion is necessary for the properdiagnosis and effective prevention of failure. Therefore, damage induced due to corrosion of reinforcing steel should be detected in the early stages and the severity ofcorrosion should be properly anticipated by means of non-destructive testing techniques for the safety of the structure.The available methods of corrosion detection in concrete structures are generallyelectrochemical, such as half-cell potential (HCP) measurements and linear polarization resistance (LPR). These methods are intrusive as they require a physicalconnection to the corroding steel. Furthermore, these methods only provide information about local corrosion and are usually used after corrosion damage is discoveredvisually. Acoustic emission is sensitive enough to be a feasible nondestructive testingtechnique to detect early corrosion. Therefore a corrosion monitoring cell to detectcorrosion in reinforced concrete beams using acoustic emission is setup for the rsttime at The University of Toledo and experiments are conducted.This thesis presents the first use of acoustic emission to detect corrosion in rein-forced concrete at The University of Toledo. The tasks accomplished includes settingup a corrosion cell and understanding the AE hardware and software equipment. Aliterature review of corrosion monitoring in reinforced concrete using acoustic emission technology is provided in order to understand the AE technology advancementto date. Corrosion monitoring experiments were designed in the laboratory to initiate corrosion in reinforced concrete in a short time span and continuously monitorwith an AE data acquisition system. Electrochemical half-cell potential method isused to anticipate the initiation of corrosion and to correlate AE data with potentialsat different stages of the experiment. Steel rebar and two reinforced concrete beamsare corroded immersing in 3.5% NaCl solution and using constant potential. Thecorrosion in these rebar and concrete specimens are monitored continuously usingMistras Pocket Corpac with R15 sensors. Half cell potential measurements are alsoconducted to understand the method and used to establish correlation with AE.The experiments conducted helped to understand the corrosion process and detectcorrosion using AE. The results of the experiments using acoustic emission were foundconsistent with those in the literature and the conclusions were conrmed using half-cell potential measurements.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Grantor dc:publisher
- University of Toledo
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Penumatsa, Gowtham, Penumatsa
- Advisor dc:contributor.advisor
-
- Nims, Douglas
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=toledo1462898129