University of Cincinnati
DETERMINATION OF THE FEASIBILITY OF USING THE PORTABLE X-RAY FLUOURESCENCE (XRF) ANALYZER IN THE FIELD FOR MEASURING THE LEAD CONTENT OF SIEVED SOIL
Abstract
dc:descriptionSoil samples collected in areas with potential lead contamination are generally analyzed using flame atomic absorption spectrometry (FAAS), inductively coupled plasma emission spectrometry (ICP-AES) or other laboratory methods. Laboratories, generally prepare sample for analyses by drying, and sieving to a homogenous fraction followed by acid digestion, all of which usually takes several days. Previous work has indicated that a field-portable x-ray fluorescence (XRF) analyzer is capable of producing soil lead results that are comparable to results by FAAS or ICP-AES. There would be considerable savings in time and effort if a field method, including sieving, could be developed which does not require laboratory digestion and analysis. Results could, therefore, be reported in a timelier manner to residents and others shortly after sample collection. The goal of this study was to determine the practicality of using the portable XRF analyzer in the field for analysis of lead on field-sieved soil samples. The practicality of using the XRF was determined by the amount of time it took to prepare and analyze the samples in the field and by the ease in which the procedure could be accomplished on site. Other objectives of the study included determining the effects of moisture on sieving the soil. When performing the field analysis, soil samples were desegregated and ground using a mortal and pestle and sieved through a No. 120 sieve pan to obtain particles <125 µm. Soil samples were obtained from yards of Cincinnati area housing built before 1978. Seventy-eight samples were collected and analyzed at 30 different locations. Mean soil lead concentrations were 816 ppm before drying and 817 ppm after drying by portable XRF, and 1042 ppm when digested and analyzed by FAAS. Correlation of field portable XRF and FAAS results were excellent for samples sieved to less than 125 µm with R-squared values of 0.992 and 0.9903 before and after drying respectively. The percent saturation of the soil ranged from 10% to 90%. At 65% saturation soil will not pass through the sieve, therefore the field method with sieving is not practical when the soil is 65% saturated or higher.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Medicine : Environmental Health Sciences
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- ARMSTRONG, ANDREA MARIE
- Advisor dc:contributor.advisor
-
- Clark, Dr. Scott
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- restricted--full text not available online
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1021653996