University of Cincinnati
FEASIBILITY STUDY FOR THE USE OF IFT TECHNOLOGY IN THE MEASUREMENT OF <i>IN-VIVO</i> CONTACT STRESSES IN THE GOAT KNEE
Abstract
dc:descriptionTo investigate the feasibility of using IFTs for <i>in-vivo</i> knee meniscus force measurements, a series of experiments were designed. The results of this study showed that 1.There is no significant change in IFT sensitivity with change in transducer orientation, 2.There is no observable saturation of transducer signals as a result of a 1000N joint contact load, 3.IFTs under sustained load do not experience a significant decrease in the magnitude of IFT voltage output, 4.Loading rate did not have a significant effect on changes in IFT output, 5.Unique physical loads cause unique combinations of IFT output under unique loading conditions although consistent patterns do not exist across knees, 6.IFT output changed significantly with changes in temperature. These results have helped us understand the performance of IFTs in the compressive environment of the knee and have shown that it may be feasible to measure electronic signals that correlate with compressive load.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering : Aerospace Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- WEST, JOHN REID
- Advisor dc:contributor.advisor
-
- Butler, Dr. David L.
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1068673427