Back to search

University of Cincinnati

BEAD-BASED IMMUNOASSAYS WITH ELECTROCHEMICAL DETECTION

Abstract

dc:description

Immunoassays with electrochemical detection have gained popularity due to their versatility, low detection limits, relatively easy procedures, and simple instrumentation. Immunoassays have a wide range of applications in clinical chemistry and biodefense as well as agricultural, environmental, and processed food areas. A variety of sensitive amperometric electrochemical detection methods have previously been used with immunoassays. A microelectrode was used here as a detector for bead-based assays in very small sample volumes (down to 10 µL) with low detection limits, fast response times, and fairly good reproducibility. A microelectrode with currents in the pA range and very low charging currents showed great promise as a detector for small volume immunoassays in a biosensor with a microfluidic component. The microelectrode helped overcome the problem of rapid depletion of the electroactive species during detection in small volumes where the macroelectrode would consume the electroactive species faster than the enzymes could produce them. The rapid depletion was seen with macroelectrodes such as the rotating disk electrode. Ovalbumin protein, a simulant for biotoxins, used as an antigen in immunoassays was characterized using ion exchange chromatography, thermal denaturation, and circular dichroism. Ovalbumin varied in the degree of phosphorylation of the two serine residues between preparations. A microvolume sandwich immunoassay for ovalbumin with enzyme labels was developed on paramagnetic beads that were easy to manipulate, presented short diffusional distances, and hence faster assay times. A rotating disk electrode at a fixed potential was used as a detector. The viability of electrochemical immunoassay as a sensitive technique in a water sample matrix was investigated. Water samples from around the country were characterized with respect to pH and metal content. Sandwich immunoassays for ovalbumin were done in finished water from Cincinnati, OH and from Potomac, MD with minor pretreatment with a chelating agent and a buffering agent. The assay was also done successfully in unfiltered pond water from Cedarville, OH.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • RONKAINEN-MATSUNO, NIINA JOHANNA
Contributors dc:contributor
  • Haisall, H. Brian
  • Heineman, William R.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

RONKAINEN-MATSUNO, NIINA JOHANNA. BEAD-BASED IMMUNOASSAYS WITH ELECTROCHEMICAL DETECTION. doctoral thesis, University of Cincinnati, 2003. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1069082511