University of Cincinnati
A STUDY OF THE BREAKTHROUGH TIMES OF 1-BROMOPROPANE AND 2 - BROMOPROPANE IN SELECT GLOVES
Abstract
dc:descriptionThe focus of this study is to determine breakthrough times of 1-bromopropane and 2-bromopropane in industrial glove materials used by industry. Three types of gloves were selected for this study and tested against the two chemicals using the American Society of Testing Methods (ASTM) -739 method. Two detection methods, a real-time monitor and a gas chromatograph were used in the evaluations to detect breakthrough times in the gloves. At the conclusion of the study, Silver Shield® was the best barrier against the two chemicals, since no breakthrough occurred. Chemical breakthrough occurred in nitrile glove after a period of 30 - 44 minutes. In the third glove, polyvinyl chloride (PVC) breakthrough occurred within 3 – 7 minutes against the two chemicals, so it is not recommended for use. Significant differences in the mean breakthrough time of different gloves of different materials were found.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Medicine : Environmental Health Sciences
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- MOORE, JOHN ROBERT, III
- Advisor dc:contributor.advisor
-
- Talaska, Dr. Glenn
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1078226621