Evaluation of Position Measurement Devices for Future Use in Obtaining <i>In-Vivo</i> Knee Joint Kinematics

Abstract

dc:description

<p>Functional tissue engineering (FTE) of meniscal replacement is a focus of orthopaedic research due to the inability of current treatment options to restore normal meniscus functions. FTE requires obtaining design parameters, which in our case are in-vivo meniscal contact stress patterns. In order to obtain these patterns, we must have accurate and reliable devices for measuring in-vivo joint kinematics and contact stresses that can be used to recreate these motions and loads in-vitro.</p> <p>The objective of this study was to evaluate the accuracy and reliability of an electromagnetic position tracking device (AuroraTM) and an ultrasonic distance measuring device (Sonometrics system) as potential tools for obtaining joint kinematics. For the Aurora system, average translational errors during static testing were 0.1 ± 0.04mm, 0.2 ± 0.17mm, and 0.8 ± 0.81mm (mean ± SD) for sensors 50mm, 300mm, and 550mm away from the field generator, respectively. Average rotational errors were 0.4 ± 0.31°, 0.4 ± 0.21°, and 0.9 ± 0.85° (mean ± SD) for sensors located at the same distances. Hourly changes in sensor signal during static testing were negligible up to 5 hours. The effects of treadmill operation on translational accuracy were negligible, and the effects of dynamic motions on sensor-to-sensor distance showed standard deviations of 2.6mm and a range of 13mm for the highest frequency tested (0.23Hz).</p> <p>For the Sonometrics system, the 2mm round and peg crystals were accurate to within 0.5mm for 0 through 180° rotations, however the 2mm round suture loop crystals were only reliable at 0° rotation. Translational errors were less than 0.072mm for crystal displacements of 0.012, 0.2, 1.0, and 5.0mm, and for dynamic motions were less than 0.45mm for 0.65Hz motion. The speed of sound through the solution (and hence the distance between crystals) versus temperature fit to a second order polynomial equation c=1421.1 + 3.9808T - 3.09 x 10<sup>-2</sup>T<sup>2</sup> with an R<sup>2</sup> value of 0.9998.</p> <p>We conclude that while the Aurora system is useful for static or slow dynamic motions it is of limited use for obtaining gait kinematics at higher speeds. The Sonometrics system is accurate and reliable both in static and dynamic conditions, and with further evaluation could be our chosen device for measuring knee joint kinematics.</p>

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering : Biomedical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schuler, Nisha Bi
Advisor dc:contributor.advisor
  • Shearn, Dr. Jason

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Schuler, Nisha Bi. Evaluation of Position Measurement Devices for Future Use in Obtaining <i>In-Vivo</i> Knee Joint Kinematics. masters thesis, University of Cincinnati, 2004. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085519312