University of Cincinnati
Bank Instability Resulting From Rapid Flood Recession Along The Licking River, Kentucky
Abstract
dc:descriptionRiver bank instability has been linked with changing land use, deforestation and channel meandering. Fluctuations in water level, either seasonal or more frequent, have also been related to instability. Increased pore water pressure has been correlated with flooding. When, the level of water decreases rapidly, the pore water pressure within the soil remains high, thereby decreasing the soil’s effective shear strength. This reduction in shear strength may result in bank failure. The banks of the Licking River near Wilder, Kentucky were selected as a study site because they exhibit instability features: tension cracks, circular and wedge failures, slumps and piping, some of which developed after a major flooding event in 1997. Tensiometers were installed at depth from 4 ft to 10 ft and a piezometer was installed at a depth of 12 ft. The bank material is clay with low plasticity (CL) with total cohesion and friction angle of 27 kPa and 13o respectively. Although soil suction was found to respond rapidly to wetting and drying, the results demonstrate the importance of antecedent events in the saturation of the slope and in the reduction of matric suction. High values of the factor of safety for slope failure were found when modeling the slope under steady-state conditions but lower values were found for rapid drawdown cases. Modeling of the slope indicates that cohesion and hydrostatic confining pressure are critical parameters in evaluating the bank stability. Thus, riverbanks are sensitive to the history of water elevation changes. soil suction fluctuates greatly due to rainfall and flooding episodes. Because this parameter is so variable, including it in the calculation of the stability of the slope may lead to overestimation of the factor of safety. Therefore, assumption of saturated conditions is more conservative. Prolonged periods of flooding or flood events with significant antecedent rainfall or other flood events cause saturation of the slope. This increases the likelihood of failure when water stage lowers rapidly. The critical water elevation was found to be below 140 m for rapid drawdown conditions after flood recession on to the Licking River.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Arts and Sciences : Geology
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Londono, Ana Cristina
- Advisor dc:contributor.advisor
-
- Nash, Dr. David
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1100631346