EVALUATION & DESIGN OF A POWER CONDUIT FOR A HEART ASSIST DEVICE
Abstract
dc:descriptionThe focus of this research is the evaluation and design of a torque transmitting mechanism in a mechanical circulatory support system for patients suffering end stage heart failure. Ventricular Assist Devices (VADs) offer hope for so many casualties of heart failure. Blood clots develop on artificial surfaces and these are the most common source of VAD morbidity. These might be avoided with a newer technology, which is more precisely controlled and is adapted from a discarded old idea of mechanical powering. Mechanical powering was used to actuate polymer membranes in VADs. Instead if the native heart walls are actuated, it might as well improve the VAD durability. Most of the mechanical circulatory support systems and devices have articulating joints and these are not safe in direct blood-contact, as the device is intended for a long term use. Therefore pulsatile VADs have a risk of fatigue failure due to the presence of continuously flexing membranes. In native heart wall actuation this risk is avoided to some extent. Direct mechanical assistance provided to native ventricular walls improves hemodynamics in failing hearts without complications associated with a blood/device interface. Previous devices in use have been able to meet the temporary needs of the patients, have failed to deliver assistance to a failing heart for a long term use. The concept of using direct mechanical assistance to the native ventricular walls for patients suffering end stage heart failure is reviewed in this study. The first clinical results introducing Anstadt Cup as a means of direct mechanical ventricular assistance showed a higher efficiency compared with closed chest compression. Some medical complications such as myocardial necrosis of the right ventricular tract, caused by pressure development in a closed system occurred, due to which the further investigation of this device was not undertaken. Another method used to provide direct mechanical assistance to native ventricular walls was by a skeletal muscle. This was able to reduce stroke work and raise blood pressure in studies conducted in animals. However one of the papers reviewed for the study, focused on a loss of function of one of the muscles caused by fibrosis and epicardial adhesions. A new concept RePower, of direct mechanical ventricular assistance is being introduced by CardioEnergetics Inc., using an implantable heart assist device. The concept of compressing the ventricles externally by providing mechanical assistance was an original idea adapted from the Anstadt Cup. It is assumed that this new concept would be an alternative to all the conventional and current treatments available to end stage heart failure. RePower is a ventricular assistance device which actuates the native ventricular walls directly by a mechanical circulatory support system. The unique design features of RePower enable it to maintain left-right pressure independence. The two ventricles are mechanically isolated by means of a flexible frame work and power drivers. The strain energy stored in a coil of wire, or a helical spring is utilized to transfer the torque to the compressing device unlike NOVACOR, a currently used VAD, that uses flat springs. This is the fundamental principle on which the RePower works. An objective of RePower development is to demonstrate that it can restore normal pumping capacity to a failing, and even permanently arrested dilated ventricle. The design concepts considered in this thesis concentrate on the power conduits. Power is transferred to the actuator mechanism fixed on to the native ventricular wall through a conduit. This conduit consists of a helical spring and discs which have slightly convex ends to prevent stiffening. Due to this arrangement, unidirectional torque is transmitted during the systolic cycle of pumping blood. Some conceptual designs are analyzed and solved and the coil of wire is modeled using Integrated Design Engineering Analysis Software (I-DEAS) developed by SDRC. A finite element model of the coil of wire(s) is solved for stresses and deflections under given loading and boundary conditions. The values of these stresses are compared with standard references for a suitable material to be chosen. After some studies Titanium alloy Ti-6 Al-4 V is chosen for the spring and the discs. This material is bio-compatible and blood-friendly. The life time of the device is estimated to be infinite (theoretically), if the calculated stresses are within a range of approximately 30 to 40 % of the ultimate strength of the material. In normal working conditions, considering the safe and convenient functioning of the device inside the human body, the device is aimed to work for an average human life time.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering : Mechanical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- MADDURI, SUSHMA
- Advisor dc:contributor.advisor
-
- Huston, Dr. Ronald
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1107884316