Abstract
dc:descriptionThis work explored the possibility of coupling of an immunoassay-based detection with microwave-based sensing in an effort to improve the overall speed of the microbial agent detection. More specifically, we attempt to improve the speed of detection of antibody-antigen binding by coupling antibodies labeled with gold nanoparticles (approximately 20 nm in diameter) and using a microwave cavity to rapidly detect them. Gold-tagged antibodies were immobilized in polyvinyldene fluoride (PVDF) membrane filters at concentrations ranging from 100 fg/L to 1 µg/L. A cylindrical microwave cavity was used to measure perturbations in the 10 to 36 GHz range due to presence of nanoparticles inside the PVDF filters. A model of the cavity and the PVDF filters was composed in FEMLAB to predict perturbations inside the resonant cavity.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering : Electrical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- PEPPLES, DAVID
- Advisor dc:contributor.advisor
-
- Papautsky, Dr. Ian
Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1116277282