GENERALIZED SENSITIVITY ANALYSIS OF WATER DISTRIBUTION SYSTEM VULNERABILITY TO DELIBERATE INTRUSIONS

Abstract

dc:description

This thesis presents a two-part investigation on the vulnerability of municipal water distribution systems to deliberate biochemical intrusions. In part 1, intrusions were modeled as a steady 6-hour injection of a soluble conservative contaminant into a randomly selected node on the pipe network of a small town. The propagation of the contaminant through the water distribution system was tracked with EPANET and, at the end of 72 hours, the fraction of the town’s population exposed to the contaminant was estimated. This was repeated for multiple injection nodes randomly dispersed across the network. A dimensionless “Exposure Index” (EI) was introduced as a simple global measure of network vulnerability: an EI value of 0 implies that no residents are exposed to the contaminant; an EI value of 100 implies that all residents are exposed. In addition, results of the intrusion simulations were used to construct a “Zone of Influence” map which categorizes the network nodes on the basis of their exposure potential. In part 2, a Generalized Sensitivity Analysis (GSA) was performed to identify which, if any, of four dynamic network variables (base demand, storage capacity, mass loading and injection duration) had a significant influence on the percentage of population exposed to the contaminant during an intrusion. Latin Hypercube Sampling was used to set-up 1152 biochemical assault simulations at each of three injection nodes. The nodes were selected on the basis of their exposure potential (high, medium or low) as indicated on the Zone of Influence map. Based on the Kolmogorov-Smirnov d statistic, simulated exposure levels were found to be most sensitive to variations in base demand and mass loading. Tank capacity and injection duration tended not to be important. More work is needed, however, to identify appropriate measures of population exposure. This exercise demonstrates that GSA holds promise as a robust tool for streamlining computationally intensive network simulation experiments.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering : Environmental Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • KHANAL, NABIN
Advisor dc:contributor.advisor
  • Buchberger, Dr. Steven

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

KHANAL, NABIN. GENERALIZED SENSITIVITY ANALYSIS OF WATER DISTRIBUTION SYSTEM VULNERABILITY TO DELIBERATE INTRUSIONS. masters thesis, University of Cincinnati, 2005. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123791754