Back to search

University of Cincinnati

Studies of Spectral Distortion Under ATR Condition in Spectroelectrochemical Sensor Development of Laser Induced Fluorescence Detection System for Multilane Capillary Electrophoresis Microchips

Abstract

dc:description

This thesis is dedicated to two separate topics. First topic is related to investigations of the optical properties of spectroelectochemical sensor. The modeling methodology of spectroelectrochemical sensor is described and applied to the Ru(bpy)32+ and Nafion film system. Ru(bpy)32+ sorption is carried out experimentally in a standard sensor configuration. Theoretical absorbance values are obtained for this system based on independently determined optical constants of Nafion film after Ru(bpy)32+ sorption. The developed methodology is applied for studies of thin film ATR spectra. Various thicknesses, pre-soaked Nafion films are studied. Spectral scans over the range of wavelength and angle of incidence reveal significant distortions for films with thickness above 200 nm. Spectra exhibit additional absorbance maxima, shifted considerably away from the true k maxima. The effect is observed if k is on the order of 0.01. Ru(bpy)32+ sorption was studied in situ and by explicit finite difference method. Significant spectral distortions are observed due to leaky waveguiding mode distortions during sorption. The second part of this thesis explores a laser induced fluorescence multi-lane detection system. Plastic materials suitable for optical detection were evaluated over the visible spectrum (403, 488, 532 and 633 nm excitations). Commercially available cyclic olefin copolymers (COC), polycarbonate (PC) and poly(methylmethacrylate) (PMMA) materials and home-made chips are investigated. COC and PMMA and represent the best materials for chip fabrications and exhibit autofluorescence only a few (3 to 5) times higher than Borofloat glass. An optical multi-lane detection system was demonstrated. A linearly expanded beam (~6 mm) was focused across 14 microfluidic channels. As a result, a fluorescent analyte could be detected simultaneously in all channels. Separation of fluorescein and fluorescein isothiocyanate was demonstrated on a glass multi-lane chip.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Piruska, Aigars
Contributors dc:contributor
  • Seliskar, Dr. Carl

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Piruska, Aigars. Studies of Spectral Distortion Under ATR Condition in Spectroelectrochemical Sensor Development of Laser Induced Fluorescence Detection System for Multilane Capillary Electrophoresis Microchips. doctoral thesis, University of Cincinnati, 2006. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1163388232