A Special Inference Problem in Repeated Measures Design with Applications to Pulse Oximetry
Abstract
dc:descriptionThe objective of pulse oximetry studies is to demonstrate that the paired repeated measurements from a pulse oximeter (SpO<sub>2</sub>) and a co-oximeter (SaO<sub>2</sub>), agree sufficiently with respect to a pre-specified agreement score. The measure of agreement in pulse oximetry studies is the Accuracy Root-Mean Square (A<sub>RMS</sub>). To account for both systematic and random components of error, pulse oximeter manufacturers have defined accuracy to represent the root-mean square between the pulse oximeter and co-oximeter values. The current methods for analyzing pulse oximetry method comparison studies are mostly descriptive. Pennello (2002) initiated the discussion on sample size calculation and test of statistical hypotheses applied to the A<sub>RMS</sub>. Using Pennello’s results as a springboard, the purpose of this dissertation was to further study the distributional properties of the ARMS and recommend sample size and test of hypothesis methodologies appropriate to this agreement score. We proposed and evaluated via simulation studies a more robust method for testing the statistical hypothesis of the accuracy of a pulse oximeter. The proposed Z-test, based on restricted maximum likelihood estimate of the between-subject variance is superior to the Pennello test; the alpha level is maintained and the power of the test is superior to the power of the Pennello test. For all configurations studied, the Pennello Z-test is conservative (undersized). The proposed Z-test is therefore highly recommended to be incorporated in future pulse oximetry studies as a test statistic of choice. The proposed Z-test would obviate the need for regulatory agencies (e.g., the FDA) to base device approval decisions on subjective assessments of accuracy root-mean square (i.e., comparing A<sub>RMS</sub> to a target of 3%). A Likelihood Ratio test was also derived and evaluated via simulation studies. It is highly recommended not to use the LRT in studies aimed at assessing the accuracy of a pulse oximeter, since the test is liberal (oversized). We also derived a sample size algorithm for testing the accuracy of a pulse oximeter and via simulation studies we evaluated the performance of the proposed algorithm. The resulting sample size should be inflated if an effect size greater than one is anticipated.
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Medicine : Biostatistics (Environmental Health)
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ndikintum, Nfii Kangong
- Advisor dc:contributor.advisor
-
- Welge, Jeffrey
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1177418766