University of Cincinnati
ISSUES IN ROBUST ONLINE HEALTH MONITORING OF STEEL STRINGER BRIDGES
Abstract
dc:descriptionThe need for instrumented health monitoring systems has been felt by the research community to observe the health of the detiorating highway infrastructure system. University of Cincinnati Infrastructure Institute(UCII) in collaboration with the Applied Systems Research Laboratory(ASRL) has been monitoring multiple steel stringer bridges. Among the various bridges monitored, an elaborate monitoring setup was installed on the HAM-126-0881L to monitor the long term and short term behavior of the bridge through high speed and low speed data collection systems. The high speed monitoring system collects vital information of the bridge as heavy trucks pass through the bridge. Each instance of a truck represents a truckload test on the bridge and the onsite monitoring system collects the data and processes it to rate the bridge as per UCII and AASHTO guidelines.[16] This is done on a real time basis. These ratings have been traditionally used by bridge inspectors to evaluate the condition of bridges. Through the continuous monitoring of the bridge ratings, the researchers at UCII/ ASRL are trying to see the detioration of the bridge as it ages. As a first attempt to developing a monitoring system and conversion of theoretical truckload test rating schemes, the UCII team was successful in collecting useful data. The following thesis has taken the data generated from the monitoring system and performed a thorough analysis of the resultant data. The analysis involved taking a dataset of 11100 individual observations from the raw data files stored on the onsite computer. The raw data files were used to extract vehicle information characteristics such as weight, speed, vehicle code, etc. The stored HS20 and UIL data was used to calculate the bridge rating for each instance of truck passage. We observed multiple cases of faulty bridge ratings in which the monitoring system misfired/malfunctioned to give us faulty ratings. A thorough analysis was done to pinpoint the possible causes and finally recommendations were made and methods suggested were successfully tested to present ways to fix cases of faulty observations.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering : Electrical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- PANIGRAHI, SAMBIT
- Advisor dc:contributor.advisor
-
- Helmicki, Dr. Arthur
Subjects
dc:subject × 3Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1179860487