Free field characterization of High Intensity Focused Ultrasound (HIFU) transducers using acoustic streaming
Abstract
dc:description<p>This work described in this dissertation addresses the problem of characterizing HIFU fields at clinically relevant power levels. Two new techniques are presented for determining the intensity distributions of HIFU transducers in liquid media. The new techniques are based upon the acoustic streaming field generated by absorption of the HIFU beam in the liquid. The streaming field is quantified using a flow visualization technique called Digital Particle Image Velocimetry (DPIV). From the experimental streaming field, acoustic intensity and power are calculated using two different approaches: i) Iterative method and ii) Direct method. In the iterative approach, an optimization algorithm is developed to compute the acoustic intensity field by iteratively minimizing the difference between a theoretical estimate of the streaming velocity and the one measured experimentally. In the direct streaming method, the differential operations of the Navier-Stokes equations are performed directly upon the experimentally measured streaming velocity to get the acoustic field. </p><p>The acoustic fields estimated using the streaming techniques were validated with the standard measurement techniques such as hydrophone scans and radiation force balance (RFB) at low power levels. Intensity fields and acoustic powers predicted using the streaming methods were found to agree within 20% with measurements obtained using hydrophones and RFB. Comparisons performed in the range 100 to 1000 W/cm2 focal intensity showed differences between the direct methods and the iterative streaming technique to be less than 20%. Besides acoustic intensity fields, the streaming technique may be used to determine other important HIFU parameters, such as beam tilt angle or absorption of the propagation medium.</p><p>Finally, the effect of acoustic non-linearities on the accuracy of the streaming techniques was studied. Results suggest that the methods as presented here are accurate in the moderate intensity regime - intensities that are high enough to potentially damage to conventional hydrophones, but below the levels where nonlinear propagation effects are appreciable. The upper range of this moderate intensity regime is approximately 1000 W/cm2. Consequently, to measure intensities beyond about a thousand W/cm2, modifications have to be made in the technique to account for nonlinear effects emerging during sound propagation.</p>
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Engineering : Mechanical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- HARIHARAN, PRASANNA
- Chair dc:contributor.committeechair
-
- Banerjee, Rupak K.
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1204570105