University of Cincinnati
Performance Aspects of Filtering Facepiece Respirators Against Ultrafine Inert and Biological Particles
Abstract
dc:description<p>Aspects of filter testing and performance of filtering-facepiece respirators (FFRs) were investigated with focus on particles in the ultrafine size range. Three specific aims were pursued in four related studies.</p> <p>In the first study, the contribution to measured concentration made by the ultrafine fraction of the NIOSH respirator filtration test aerosols was theoretically modeled and tested. The most-penetrating particle size (MPPS) for N-type filters was observed in the ultrafine size range under laboratory conditions; also, ultrafine particles did not materially contribute to NIOSH’s respirator filter test protocol.</p> <p>The second study compared filter penetration and MPPS for N99 and N95 FFR’s when challenged with ultrafine inert (NaCl) and biological aerosols (3 test viruses). The MPPS was observed in the ultrafine size for all respirators and test aerosols under conditions similar to the NIOSH filter test protocol. Inert particles penetrated filters similarly to virus particles, with several exceptions which were explainable and attributed to the physical and electrical properties of virus particles.</p> <p>The third study developed and evaluated a method to compare physical and biological (viable count) filtration efficiency of two traditional respirators and one newly designed FFR with an iodinated treatment. The physical and viable virus penetrations were not found to differ for all three respirators; no killing effect was observed in virus particles which penetrated the filter medium.</p> <p>An additional study assessed the appropriateness of nebulization to aerosolize virions for use in filter testing. An experiment was conducted to compare bioaerosol filter testing using nebulization to that of charge-reduced electrospray. The nebulizer protocol was observed to be reasonably robust and it was concluded that nebulization is an appropriate method to use for aerosolizing virions for filter testing with appropriate protocols.</p> <p>Overall, this dissertation contributed several key observations: (1) the definition of the "most conservative" test conditions for respirator filter testing was refined; (2) the understanding of factors which contribute to filtration differences of ultrafine biological and inert particles was increased; (3) a novel method was developed to differentiate physical and viable bioaerosol filter penetrations, and (4) the first practical comparison of nebulization and electrospray for aerosolizing virions was performed.</p>
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Medicine : Environmental Health
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Eninger, Robert M.
- Chair dc:contributor.committeechair
-
- Grinshpun, Sergey
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1217858522