Back to search

University of Cincinnati

Development of methods to determine the binding capacities of solid supports and improvement in immunoassay efficiency using dendrimer-modified beads

Abstract

dc:description

<p>A rapid and sensitive fluorimetric assay has been developed to determine the biotin-binding capacities (BBC) of streptavidin or NeutrAvidin™ coated solid supports and therefore to estimate immobilized streptavidin/NeutrAvidin™ concentration. Biotin-4-fluorescein (b-4-f) on binding with streptavidin/NeutrAvidin™ gets quenched. A series of titrations were done using b-4-f as titrant for streptavidin/NeutrAvidin™ solid supports. Break points of titrations were used to determine total BBC. This method was successfully tested on four different solid supports – 2.8 µm streptavidin magnetic beads (4 × 10<sup>6</sup> biotin/bead), 2.8 µm NeutrAvidin™ magnetic beads (2 × 10<sup>6</sup> biotin/bead), 0.31 µm non-magnetic streptavidin polystyrene blue particles (6 × 10<sup>3</sup> biotin/particle) and a 96 well streptavidin micro-titer plate (5 × 10<sup>13</sup> biotin/well). </p><p>Another Fluorimetric method has been developed to determine the ligand binding capacities of streptavidin/NeutrAvidin™ coated solid supports. Streptavidin/NeutrAvidin™ coated solid supports were titrated with biotinylated antibodies followed by addition of b-4-f. Antibody concentration at the asymptote intersection (saturation point) was used to determine the ligand-binding capacity of four different solid supports as above. Streptavidin (2.8 µm) beads showed approx. 15fold decrease, streptavidin particles (0.31 µm) had 4fold decrease while streptavidin coated polystyrene plates, exhibited approx. 25fold decrease in biotinylated antibodies than their respective BBC published by manufacturers. Method can also be applied to determine the unknown concentration of biotinylated ligand in the solution. A calibration graph of ‘streptavidin high binding capacity coated plate’ vs. biotinylated antibody showed the linear range as 0.07 – 1.2 µg/well (4 – 65 nM) and a detection limit of 0.5 nM.</p><p>The effect of different generations of dendrimers on concentration of immobilized biotinylated ligands was studied. PAMAM dendrimer of generations G5.5 and G6.5 were covalently linked to tosyl beads (2.8 µM), and NeutrAvidin™ was covalently attached to the C-terminal of the dendrimer using EDC-sNHS coupling. All beads were finally coated with biotinylated antibodies. Moles of antibodies bound per bead for each generation of dendrimer vs. plain streptavidin/NeutrAvidin™ beads were compared using fluorescence. The amount of antibody bound per bead showed a trend with an increase in number of antibodies per bead from generations G0.5 to G6.5. There was an approximately 10fold increase in the number of antibodies bound per bead for G6.5 dendrimer (4 × 10<sup>6</sup> antibodies/bead) versus plain NeutrAvidin™ coated beads (4 × 10<sup>5</sup> antibodies/bead). Also, G6.5 beads showed 4.5fold increase in biotin binding sites than plain NeutrAvidin™ beads. Finally G6.5 dendrimer-NeutrAvidin™ beads and plain NeutrAvidin™ beads (both coated with antibody) were used as capture beads for an immunoassay and G 6.5 dendrimer- NeutrAvidin™ beads gave 5fold higher immunoassay sensitivity than plain NeutrAvidin™ beads.</p><p>The effect of different water disinfectants on immunoassay sensitivity was studied in our laboratory and it was found that oxidizing disinfectants chlorine and monochloramine had major effect on the sensitivity of MS2 bacteriophage. Hence the effect of different concentrations of monochloramine and its individual components on immunoassay sensitivity was studied for MS2 bacteriophage. It was found that decrease in immunoassay sensitivity was due to the combined or individual effect of monochloramine components (chlorine and ammonia).</p>

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tiwari, Umadevi B.
Chairs dc:contributor.committeechair
  • Halsall, H Brian
  • Heineman, William

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Tiwari, Umadevi B.. Development of methods to determine the binding capacities of solid supports and improvement in immunoassay efficiency using dendrimer-modified beads. doctoral thesis, University of Cincinnati, 2009. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1259077463