Back to search

University of Cincinnati

Bead-based Immunoassays for Detection of Mircoorganisms in Water

Abstract

dc:description

The goal of this research was to continue the challenging process of development, improvement and innovation of bead-based immunoassay for the detection of microorganisms in water started earlier by other group members.A bead-based sandwich immunoassay for the fluorescence detection of ovalbumin was improved and optimized. Our research group had been working for a long time to make this assay reproducible and reliable. The major improvements in the increased sensitivity and reproducibility of results were achieved after changing the anti-ovalbumin antibody provider. The assay was made more robust and more reagent efficient by switching from biotin-streptavidin conjugation to custom commercial conjugation for the enzyme labeled secondary antibody. The immunoassay was optimized and tested for the selected possible drinking water interferences water hardness (Ca<sup>2+</sup>, Mg<sup>2+</sup>), iron, phosphate, pH 9.5 and pH 6.5, fluoride, chlorine and monochloramine. The limit of detection was found to be 0.05 µg/mL. The immunoassay was significantly affected by chlorine and to a lesser degree by monochloramine in the water. The other components tested showed no effect.A vast amount of research has been done to develop bead-based fluorescence detection immunoassay for the determination of live <i>Escherichia coli (E. coli)</i>. The principle for the detection of only live bacteria was to induce bead captured cells to produce intrinsic enzyme. The enzyme then was released from the cell and detected. The amount of enzyme produced was proportional to bacteria captured by beads. Each parameter and step of the assay was questioned and a better, more efficient alternative to improve the detection was sought. To test stability and reliability, the immunoassay was evaluated using different spiked water matrices. The total analysis time including washing and handling steps was about 4 h, and the limit of quantification (LOQ) was 8 x 10<sup>4</sup> cfu/mL. The LOQ is high when compared to the EPA requirements for the acceptable <i>E. coli</i> detection method with LOD of 1 cfu/mL, but is comparable to the other ELISA type methods developed. But the LOQ can be lowered by increasing assay time to produce more enzyme. As it stands, immunoassay would be hard to use as a reliable quantification method, because it was affected by different water matrices and the two strains that were tested produced different amounts of enzyme.The initial goal for the development of live <i>E. coli</i> immunoassay was to implement this assay in a portable microfluidic device and use the instrument for field studies as a first alarm of <i>E. coli</i> pollution. For the out-of-the-lab instrument and method it is very important to have all reagents controlled, temperature and long term storage stable. Antibodies in most cases are fragile, making very careful handling with an appropriate storage temperature a requirement. Therefore, we explored the possibility to replace the antibodies with another reagent to capture bacteria on the paramagnetic beads. Dr. Iyer’s group in our department is doing research on the synthesis of carbohydrate ligands for the recognition of microorganisms. Compared to antibodies, carbohydrate ligands are robust and have long shelf-life. The Iyer group synthesized biotinylated mannose glycoconjugate for the detection of <i>E. coli</i> and we evaluated its use for the detection of live bacteria. The immunoassay innovated with carbohydrate based ligand had the same sensitivity and detection limit compared to the assay with antibody. However, when capture efficiency was compared in different pH solutions, the ligand was not so significantly affected by harsh pH values as was the antibody.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jurkevica, Agnese
Chair dc:contributor.committeechair
  • Heineman, William

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Jurkevica, Agnese. Bead-based Immunoassays for Detection of Mircoorganisms in Water. doctoral thesis, University of Cincinnati, 2010. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1267625497