Abstract
dc:description<p>Magnetic resonance spectroscopy (MRS) is a non-invasive andnon-destructive in vivo technique available on magnetic resonanceimaging (MRI) scanners that is used to measure biochemical profilesfrom localized regions, or volumes-of-interest (VOIs), inside thebody. A confounding factor for interpretation and analysis of MRS isspatial inconsistency in selection of VOIs for data collection, whichmay obscure biochemical alterations and reduce the statistical powerof a study. Because VOI selection is performed manually by the MRIoperator, consistency both between sessions and among subjectsrequires careful protocol design and experienced staff. Inter-subjectanatomic variation, imprecise experimental protocols, andinter-operator variation contribute to VOI positioning error.</p><p>In this work, automatic targeting of VOIs using a standard anatomicatlas was hypothesized to improve spatial consistency for VOIs, bothamong subjects and between sessions. Subject anatomy is aligned to atemplate during acquisition of routine high-resolution 3D anatomicimaging. Alignment is computed parallel to acquisition and completesprior to the end of the scan allowing immediate use of the templatecoordinate system for the next scan. Once aligned, preselected VOIsare transferred from the template for acquisition. Two real-timealignment techniques are compared. The first performs affinealignment of the subject to the ICBM452 template, and the secondrigidly aligns subject anatomy between baseline and followup sessions.</p><p>The technique was developed using simulations based on archived datafrom 79 subjects randomly segregated into training (40 subjects fordevelopment) and testing groups (39 subjects for evaluation). Theaccuracy of real-time spatial normalization was evaluated asdisagreement with SPM5-derived nonlinear normalization. Mediandisagreement within the brain was 1.9 mm (largest: 9.1 mm). Forcomparison, optimal affine alignment was computed directly fromnonlinear SPM5 results and had a median disagreement of 1.7 mm(largest: 7.7 mm). Median inter-session (test-retest) disagreementwas 0.4 mm (largest: 1.9 mm) for the ICBM452-based technique and 0.2mm (largest: 0.7 mm) for the rigid-body technique. Comparable resultson training and testing groups indicate good generalization of bothtechniques beyond the training group.</p><p>Automatic and manual prescription of MRS was compared for VOIs in theanterior cingulate gyrus (ACG) and left and right inferior frontalgyri (L-IFG and R-IFG). Automatic ICBM452-based selection ofnonoblique VOIs improved inter-subject overlap by +19.6%, +29.6%, and+22.4% (ACG, L-IFG, and R-IFG), and inter-session overlap by +16.2%,+15.7%, and +11.3% compared to manual VOI selections. AutomaticICBM452-based prescription of oblique VOIs provided furtherimprovements for inter-subject overlap (+1.0%, +1.4%, +1.1%) andinter-session overlap (+3.0%, +3.2%, +2.7%). Rigid-bodycoregistration further improved inter-session overlap compared toICBM452-based normalization both for nonoblique (+3.0%, +3.2%, +2.7%)and oblique (+0.6%, +0.3%, +0.6%) VOIs. Quantitative comparisons ofVOI tissue content demonstrated improved anatomic consistency forautomatic prescriptions compared to manually selected VOIs.</p><p>The availability of rapid, atlas-consistent inter-subject alignment isexpected to simplify experimental protocols while simultaneouslyimproving study-wide consistency. These improvements are expected toincrease statistical power for group comparisons, facilitateatlas-based research (including combined fMRI and MRS studies), andsupport the development of biomarkers.</p>
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Biomedical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Storrs, Judd M.
- Chair dc:contributor.committeechair
-
- Lee, Jing-Huei
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1282576722