Abstract
dc:descriptionThe lack of a cognitive and haptic interface for catheter medical devices presents a significant challenge in the intervention and treatment of aneurysms and/or stenosis in neuroscience applications. Intellectual properties in the form of sophisticated steerable catheters using piezoelectronic and bidirectional magnetic technologies exist. However, the development and adoption rate of such technologies are impeded due to the expensive cost including ancillary equipment and software needed to setup the technology platform. Additional impediments include the lack of integration into current catheter technologies, steep learning curve, and lack of accurate human to device interface transition relationships (i.e. output does not accurately represent user input). Furthermore, reliable test methods of evaluating these new technologies and user input torque response have not been fully developed -creating limitations when comparing the current state of the art devices versus proposed haptic, catheter interface solutions.In this study, systematic methods for descriptive analysis of twenty-four (24) diagnostic cerebral angiograms have been digitally recorded (video and/or still photography) and summarized leading to concept generation of a haptic interface that is a contiguous extension of the haptic unit – the human hand. This contiguous extension of the hand enables an expanded range of effector motions and control. Additionally, process development toward prototype generation is explained using a silicone resin composite, which is compatible with overmolding techniques of small wall thicknesses. The proposed haptic catheter interface has been validated through a novel test model as compared to the current state of the art device, which collects metric such as user induced torque, angle of rotation, mechanical power, and time for completion. Haptic catheter interface and usability test model data using common rotary torque sensors and processing techniques have been investigated and performed in studies, yielding a discussion of benefits and limitations for the proposed catheter interface design solution.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Biomedical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wirtz, Michael
- Chair dc:contributor.committeechair
-
- Johnson, Jeffrey
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1288982910