Active Tonal and Broadband Noise Control for Magnetic Resonance Imaging Systems
Abstract
dc:descriptionMagnetic resonance imaging (MRI) is a powerful medical diagnostic tool. It offers advantages over other common medical imaging processes. For example, MRI is capable of producing high contrast images of soft tissue and does not use potentially harmful radiation.The imaging procedure requires the subject be placed in a high strength static magnetic field. Next, the patient is subjected to magnetic field gradients that are rapidly altered and interspersed with precisely timed radio frequency transmissions and measurements. The magnetic field gradients are created by transmitting electrical current through gradient coils, which unfortunately produces loud noise during the scanning procedure. This noise is a function of the static magnetic field strength and gradient signal, both of which are essential to the procedure. It is loud enough to be unpleasant, and has the potential to be harmful. In specific applications the sound pressure level may be great enough to be a limiting factor in determining imaging protocol.The unfortunate side effect of noise production has been recognized since the advent of MRI. Engineers and scientists have proposed a variety of approaches to address the problem. Unfortunately, there has been limited success in developing a practical, cost effective solution that is applicable to a wide range of scanners.This dissertation will address the development of an active noise control system specifically designed to attenuate tonal and broadband noise generated during magnetic resonance imaging. In order to develop an ANC system capable of operating in the magnetic environment, non-ferromagnetic speakers and microphones were tested and implementation procedures developed that allow for optimal performance. Due to the high cost of operating the MRI scanner, a physical simulation environment including noise and MRI gradient signals was created to allow for testing during the development process. A control system capable of providing significant noise reduction at frequencies up to 5 kHz was developed and tested for multiple common MRI scanning sequences. These scanning sequences exhibit different frequency and temporal characteristics and were selected with the goal of developing a robust control system capable of being tuned for a wide variety of imaging sequences. Finally, the ANC system was evaluated at the University of Cincinnati's Center for Imaging Research. The ANC system was interfaced with the equipment controlling the 4 T Varian Unity INOVA Whole Body MRI/MRS system. Live scanning sequences were conducted, and the ANC system's performance measured and reported. Data from the in-situ test will be presented that shows the ANC system provides substantial overall noise reduction for each of the three scanning sequences conducted. The maximum reduction measured during the in-situ scan for a specific harmonic was 55 dB during a gradient echo multi-slice (GEMS) scan, with 30 dBA overall reduction across virtually all harmonics up to 5 kHz.
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Mechanical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rudd, Brent
- Chair dc:contributor.committeechair
-
- Lim, Teik
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1298042881