Back to search

University of Cincinnati

Numerical Analysis of Heat Transfer Enhancement and Pressure Drop Reduction for an A-frame Air Cooled Steam Condenser

Abstract

dc:description

Air cooled steam condensers (ACSC) consist of finned-tube arrays bundled in an A-frame structure. Inefficient performance under extreme temperature operating conditions is a common problem in ACSCs. The purpose of this study was to improve the heat transfer characteristics of an annular finned-tube system for better performance in extreme climatic conditions. Perforations were created on the surface of the annular fins to attain maximum increase in heat transfer coefficient (h) and minimum increase in pressure drop (ΔP). Numerical computations were performed using finite volume method with RNG k-e turbulent model to calculate h and ΔP. Solid (no perforations) finned-tubes were simulated with free stream velocity ranging be-tween 1 m/s - 5 m/s and validated with the published data. Computations were performed for perforated (perforations at ±60° to ±180° with 30° interval) finned-tubes, followed by five cases of a single perforation and three cases with multiple perforations. Later, the spacing of the fins along the arms of A-frame ACSC was altered to decrease ΔP across the finned-tube array. The increase in h and ΔP values for perforated fins was 7% and 12% respectively as compared to the solid fins. Perforation located in the wake area, at 120°, gave favorable results with 2.2% in-crease of h and only 1.4% increase in ΔP. Multiple perforations (at 120°, 150°, 180°) resulted in 4.9% increase in h and 3.9% increase in ΔP. Perforations in the downstream region, at 120°, 150° and 180°, resulted in better heat transfer rates as compared to the upstream region. Fin spacing in the A-frame structure with sparsely spaced fins in the center resulted in 1.8% reduction in ΔP. Results showed that perforation at 120° had balanced results with maximum h and minimum ΔP. Multiple perforations can be used to obtain higher h values, provided the increase in ΔP is allowable. Also, additional reduction in ΔP can be achieved by using clustered fin spacing at the inlet and top ends of A-frame structure and large spacing at the center.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Mechanical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karve, Madhura Shreeram
Chair dc:contributor.committeechair
  • Banerjee, Rupak

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Karve, Madhura Shreeram. Numerical Analysis of Heat Transfer Enhancement and Pressure Drop Reduction for an A-frame Air Cooled Steam Condenser. masters thesis, University of Cincinnati, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1307440507