Back to search

University of Cincinnati

Optimization and construction of passive shim coils for human brain at high field MRI

Abstract

dc:description

When scanning the human brain with high-field MRI, local susceptibility variations can lead to field inhomogeneities that cause artifacts such as image distortion and signal loss. Active shimming improves homogeneity by applying corrective fields generated from shim coils, but requires calculation of optimal current for each shim coil. In chapter two, we discuss the computation of the calibration table to generate optimal active shim field and improve the field homogeneity within the human brain and a phantom. A modified 3D gradient-echo pulse sequence was implemented to obtain B0 field maps of the phantom at 4T. The magnetic field distributions of the first- and second-order shim coils were determined by assuming that the spherical harmonic coefficients of each shim coil follow the linear relationship with the settings of the DAC (Digital to Analog Converter, which controls the voltage across the different shim coils). The calibration table was determined for the optimization of all first-order and second-order shim currents. By updating the first-order and second-order active shim system using the derived calibration table, a significantly improved field distribution within the phantom was obtained.Local susceptibility variations within the human brain can lead to field inhomogeneities that degrade image quality. Improvements have been demonstrated using high-order shims at fields greater than 3T. However, due to space limitations within the magnet bore, most MRI systems provide, at most, second-order active shims. In chapter three, we present a local third-order passive shim design for improvement of field homogeneity in the brain. A 3D gradient-echo pulse sequence was used to obtain brain B0 field maps of four subjects at 4T. The B0 field maps for each subject were then decomposed into third-order spherical harmonic coefficients and averaged. Optimized positions for placement of shim elements on a cylindrical shim tube that fits over the RF coil were then computed to reduce the third-order harmonics over the entire human brain. When combined with first- and second-order active shimming, the passive shim tube significantly improved B0 homogeneity within the brain. The orbitofrontal cortex (OFC) area plays a critical role in human brain functions. However, the great mismatch in magnetic susceptibility between paranasal sinuses and the surrounding tissues of the nasal cavity leads to local susceptibility-induced field variations in the OFC that lead to imaging artifacts such as image distortion and signal loss. In chapter four, we discuss the use of magnetic material to generate the modified dipole passive shim field and improve the field homogeneity within a group of subjects’ brains, particularly in the OFC. A 3D gradient-echo pulse sequence was used to obtain B0 field maps. The half cylindrical geometry (i.e. the basic passive shim geometry) for mounting shim elements was determined. The positions of the shim elements for each harmonic component were computed with adaptation for passive shim design, which is to be placed below the chin. After the selection of appropriate positions and the corresponding dipole field amplitudes, the required susceptibilities and dimensions were determined. This study has demonstrated that the accurate placement of the appropriate diamagnetic and ferromagnetic material on the surface of the half-cylinder could generate the desired local dipole passive shim field, which causes the B0 inhomogeneity to reduce significantly over the sinus region within the human brain, especially in the OFC. In conclusion, a shim system that combines the first- and second-order active shimming, the third-order passive shimming, along with a local dipole neck-passive semi-cylinder shimming, can significantly improve B0 homogeneity within the brain at 4T.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences: Physics
Grantor dc:publisher
University of Cincinnati
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jayatilake, Mohan L.
Chairs dc:contributor.committeechair
  • Endorf, Robert
  • Lee, Jing-Huei

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Jayatilake, Mohan L.. Optimization and construction of passive shim coils for human brain at high field MRI. doctoral thesis, University of Cincinnati, 2011. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1313772791