Experimental study of saturated pool boiling in water with a fluorinated reagent
Abstract
dc:descriptionSaturated, nucleate pool boiling on a horizontal, cylindrical heater in aqueous solutions of a zwitterionic fluorosurfactant (FS-50) has been experimentally investigated. FS-50 is a long chain molecule of fluorinated carbon atoms, and it produces very low dynamic surface tension in aqueous solutions (varying from 75 x 10-3 N/m to 16.8 x 10-3; N/m, depending upon both surface age and concentration). The time scale or surface age for complete interfacial relaxation ranges from 10e-2 seconds < τ < 8 seconds. Boiling curves (given by the variation of wall heat flux with wall superheat) and photographic records of the ebullient behavior are presented, along with a detailed characterization of the interfacial behavior of the aqueous solutions and its interplay with boiling. It is seen that nucleate pool boiling behavior of water is significantly altered by the addition of FS-50, and the heat transfer is increased considerably. The enhancement in boiling is seen to stem from the dynamic changes in the interfacial tension and its overlapping timescale with that of boiling. A rather complex interplay of dynamic interfacial tension and surface wetting changes due to varying surfactant concentrations is seen to affect the phase change ebullient dynamics and associated heat transfer. In order to develop a scaling modal for predicting heat transfer for nucleate pool boiling in aqueous reagent solutions an attempt has been made to scale them with the interfacial properties. To do this, apart from the present results, data for few other (SDS (anionic), CTAB (cationic), TRITON X-100 (non-ionic)) are considered along with heat transfer results from previously published studies. It may be noted that FS-50 is a zwitterionic reagent. This scaling has been based upon modeling of the adsorption-desorption mechanisms of the reagent, and their influence on bubble dynamics associated with boiling.The proposed scaling method is derived using the existing theoretical deductions in the literature. A scaling parameter based on the most relevant dynamic interfacial property is developed and used to predict the heat transfer in aqueous solution of reagents. The proposed method works within 95 % agreement with the experimental values.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Mechanical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Verma, Utkarsh
- Chair dc:contributor.committeechair
-
- Manglik, Raj
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1343085793