Back to search

University of Cincinnati

Altering time compression algorithms of amplitude-integrated electroencephalography display improves neonatal seizure detection

Abstract

dc:description

ObjectivesPrimary objective: Determine the aEEG time compression algorithm which maximizes sensitivity and specificity for the identification of neonatal seizures. Secondary objectives: 1) Quantify the effect of prior EEG reading experience on user sensitivity and specificity of aEEG for identification of neonatal seizures. 2) Identify the contribution of concurrent unprocessed single-channel raw EEG tracing to the final sensitivity and specificity of aEEG.MethodsFull, neonatal montage, conventional EEG (cEEG) recordings from 24 neonates >36 weeks gestation and < 28 days of life were obtained. Representative 6 hr segments of cEEG including a mix of normal brain activity and abnormal seizure activity were converted to amplitude integrated EEG (aEEG) using Stellate Harmonie&#xae; software. Six different aEEG formats were created: 6cm display per hour live recording, 12cm/hr and 24cm/hr each presented with and without accompanying unfiltered single channel cEEG tracing. Two readers with extensive experience interpreting cEEG and two without that experience interpreted each study. Each reader&#x2019;s results were compared to the interpretation of the original neonatal cEEG by an expert in neonatal electrophysiology. Comparisons were used to generate sensitivity, specificity and classification accuracy for each reader and method. A theoretical clinical model assessed the impact of detected differences on clinical decision making. ResultsTwenty four 6 hour recordings were presented in 6 different formats to each reader. Thus, each reader interpreted 864 hours of aEEG. When combining studies and readers, sensitivity improved from 39% to 53% when aEEG compression decreased from 6cm/hr to 24cm/hr. When aEEG was accompanied by unfiltered single channel cEEG tracing sensitivity improved from 30% to 55% as aEEG compression was reduced. Specificities improved with reduced compression from 70% to 77% with no accompanying cEEG and ranged from 82%-90% with accompanying unfiltered cEEG signal though trend was downward with reduced compression due to increased false positives. Classification accuracy improved from 53% to 70% as aEEG compression was reduced and unfiltered cEEG signal was included for interpretation. When data was analyzed by reader type, readers with extensive experience interpreting cEEG outperformed readers without extensive experience interpreting cEEG in 81% of direct comparisons. The readers were equal in 9.5% of direct comparisons, and the inexperienced readers outperformed the experienced readers in 9.5%, of which 7% was accounted for by a single test format (24cm/hr without unfiltered cEEG) in which experienced readers identified a higher number of false positives.Clinical decision modeling showed that experienced readers made about one less error in interpretation per 6hr recording. ConclusionsOur study confirms that decompressing traditional aEEG signal from 6cm/hr to 12cm/hr or 24cm/hr improves the sensitivity and specificity as well as the classification accuracy of aEEG. When readers with extensive experience in conventional EEG are available, adding raw tracing to the aEEG generally enhances these effects. Given the potential shortcomings of aEEG, it is best used as part of a comprehensive clinical monitoring protocol where cEEG and expert neurologic interpretation of neurophysiologic data are available when clinical suspicion combined with aEEG monitoring identifies suspected seizure activity.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Medicine: Clinical and Translational Research
Grantor dc:publisher
University of Cincinnati
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Thomas, Cameron W.
Chair dc:contributor.committeechair
  • Haynes, Erin Nicole

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Thomas, Cameron W.. Altering time compression algorithms of amplitude-integrated electroencephalography display improves neonatal seizure detection. masters thesis, University of Cincinnati, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367926003