University of Cincinnati
Influence of geometric and flow variations on coronary diagnostic parameters: An in-vitro study
Abstract
dc:descriptionIn current practice, diagnostic parameters, such as fractional flow reserve (FFR) and coronary flow reserve (CFR), are used to determine the severity of a coronary artery stenosis. These parameters are evaluated from pressure and/or flow information, using sensor-tipped guidewire advanced into an artery at maximal vasodilation (hyperemia) condition. FFR is defined as the ratio of hyperemic pressures distal and proximal to a stenosis. CFR is the ratio of flow at hyperemic and basal (resting) condition. In addition to these, new diagnostic parameters have been suggested to overcome the shortcomings of the conventional parameters. Three such parameters assessed in this study are pressure drop coefficient (CDP), lesion flow coefficient (LFC), and stenotic resistance index (Rs). CDP is defined as the ratio of the pressure drop across the stenosis to the upstream dynamic pressure. LFC is the ratio of pressure drop coefficient at high Reynolds number to the pressure drop coefficient based on pressure drop across stenosis and throat dynamic pressure. The Rs is assessed by taking the ratio of hyperemic pressure drop to flow rate.These parameters may be influenced by variations in geometric and flow conditions. This study investigated whether the newly developed parameters had an advantage in areas where FFR failed to diagnose stenosis severity. Four major issues were addressed. Firstly, the influence of native arterial diameter was investigated, followed by an assessment with variation in vasculature status. The latter is an important comparison, since it is a topic of current debate, and this analysis adds to the pool of data currently available. The impact of a newly designed guidewire on the diagnostic parameters was also tested. Another important aspect of this study was to present a proof-of-concept analysis for basal based parameters.In-vitro experiment coupled with pressure-flow relationships from human clinical data was used to simulate pathophysiologic conditions in two representative arterial diameters, 2.5 mm (N1) and 3 mm (N2). With a 0.014' and newly designed 0.022' guidewire inserted separately, diagnostic parameters were evaluated for mild (~ 64% area stenosis (AS)), intermediate (~80% AS), and severe (~ 90%AS) stenosis for both N1 and N2 arteries, and between two conditions: with and without myocardial infarction (MI). From the obtained experimental data, diagnostic parameters were assessed at basal condition of 42 ml/min and 50 ml/min, for N1 and N2 respectively. Arterial and guidewire diameter did not influence FFR for clinically relevant cases of mild and intermediate stenosis (difference< 5%). Newer parameters varied considerably, but had distinctive increasing trend, which allowed stenosis delineation. However, FFR was overestimated (mild: ~9%, intermediate: ~20%, severe: ~30%) for MI. Overestimation of FFR may affect clinical decision making. CDP had variation with vascular condition (mild: ~35%, intermediate: ~14%, severe: ~9%). The value of Rs also showed similar variation (mild: ~30%, intermediate: ~25%, severe: ~14%). LFC varied somewhat (<8%) for intermediate and severe stenosis. All parameters delineated stenosis in presence of MI, overcoming the disadvantage of FFR. Of the three new parameters, CDP's wide range allowed better delineation of stenosis severities irrespective of hyperemic or basal conditions.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Mechanical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Goswami, Ishan
- Chair dc:contributor.committeechair
-
- Banerjee, Rupak
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367937429