University of Cincinnati
Optimization of the Fin Configuration of Air-cooled Condensing Wet Electrostatic Precipitator for Water Recovery from Power Plant Flue Gas
Abstract
dc:descriptionGrowing concerns about freshwater availability increase the pressure on power plant to reduce water usages. The Innovations for Existing Plants Program from the US Department of Energy's National Energy Technology Laboratory is developing technologies in 5 categories to reduce water use. One of them is reclaiming water from combustion flue gas for usage as cooling water make-up. Considering that heat transfer efficiency is significantly enhanced in both gas and liquid phases due to corona wind and wetted wall inside the wet ESPs, a innovative technology of applying air-cooled condensing wet ESP for water recovery from flue gas was proposed. Additionally, the preliminary results show that the quantities of water extracted by the proposed air-cooled condensing wet ESP far exceed the FGD water make-up. However, the optimization of wet ESP's fin configuration is at an early stage, and the operation condition effects on the determination of optimal fin's configuration are not investigated yet. Thus, in this research, an analytical model of heat process in air-cooled condensing wet ESP system was developed to predict the heat transferred from flue gas to cooling air and the condensation rate of water vapor in the flue gas. Optimum fin's thickness and spacing under the operation conditions of 80°F ambient temperature and 5MW fan power were evaluated. In addition, the effects of fan power and ambient temperature on the determination of optimal fin's configuration and water recovery are investigated. It is found that the optimal fin's thickness is 0.25 inches, and the optimal fin's spacing is 0.5 inches with 5MW fan power, and outside cooling air temperature of 80 °F. Under these optimized parameters, the total amount of water recovery reaches 557.725 gpm. Furthermore, changing ambient temperature has no effects on optimal fin's configuration, while increasing fan power make the optimal fin's thickness and spacing shift to lower value.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Engineering and Applied Science: Chemical Engineering
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Chen, Yanhui
- Chair dc:contributor.committeechair
-
- Khang, Soon Jai
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin1384334785