Back to search

University of Cincinnati

Development of Energy-Based Endpoints for diagnosis of Pulmonary Valve Insufficiency

Abstract

dc:description

Introduction. Pulmonary insufficiency (PI) causes myocardial dysfunction and hypertrophy in the right ventricle; with fatal consequences in some cases. The only remedy is pulmonary valve (PV) replacement surgery, the timing of which is critical. Surgery performed earlier than neces-sary leads to a re-emergence of PI, whereas a delayed intervention can potentially render the re-placement futile. There are no physiological markers to determine the correct window for this surgery. Clinicians currently rely on subjective assessment of cardiac MRI scans and evaluation of a few ad-hoc measures, such as end-diastolic pressure, cardiac volume and regurgitant frac-tion. The use of these different measures often results in conflicting conclusions and error-prone decisions. Thus, a quantitative index is required to unambiguously assess the progression of PI to determine the correct window for the PV replacement surgery. In this research, a set of energy-based endpoint were investigated that combined the pressure and volumetric measures. Right ventricular (RV) stroke work, energy loss in the branch pulmonary artery (PA) and a new end-point, energy transfer ratio defined as the ratio of the total blood energy at the main PA and stroke work were developed and tested as a proof-of-concept. Methods. The energy based endpoints were obtained for a normal and a diseased subject. Pres-sure measurements obtained invasively from cardiac catheterization, and flow rate and ventricu-lar volume obtained non-invasively from MRI scans were utilized for the calculation. Subsequently, methodologies to obtain these endpoints in a completely non-invasive ap-proach, using patient-specific image-based hemodynamic models were developed to eliminate the requirement of invasive catheterization. Angiographic MRI was used for geometry recon-struction for image-based models. Actual time- and spatially- varying velocity profiles, directly obtained from phase-contrast MRI were used for patient-specific velocity boundary conditions. Flow rates from the numerical models were validated with ones obtained from a standard of care measurement. Finally, the arterial wall compliance was incorporated in the computational mod-els. The in-vivo wall pre-stress was calculated by developing a nonlinear least-square based in-verse elastostatics algorithm called the shrink-and-fit inverse method. Results. The RV stroke work for the normal subject (0.115 J) was 32% higher than that of the subject with PI (0.078 J). The energy transfer ratio for the normal subject (1.06) was nearly two times that of the subject with PI (0.56). Validation of non-invasive method: The maximum difference between the flow rate from com-putation with time- and spatially-varying velocity boundary conditions and the one from standard of care measurement was 7 ml/sec at the main PA of the diseased subject. The computed flow rates for the normal subject were within 3.4% (2 ml/sec) of the measured values at each of the inlet and outlets. For the compliant arterial wall model, the shrink-and-fit inverse algorithm matched the in-vivo and pre-stressed artery geometry within 0.0015 mm. Conclusions. The energy-based endpoints were able to delineate a normal physiology from a PI pathophysiology. These endpoints have the potential to improve the diagnosis of PI by eliminat-ing the ambiguity resulting from the use of either pressure-based or volume-based measures.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering and Applied Science: Mechanical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Das, Ashish
Chair dc:contributor.committeechair
  • Banerjee, Rupak

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Das, Ashish. Development of Energy-Based Endpoints for diagnosis of Pulmonary Valve Insufficiency. doctoral thesis, University of Cincinnati, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1384864758