Back to search

University of Cincinnati

Novel System Design For Residential Heating And Cooling Load Shift Using PCM Filled Plate Heat Exchanger And Auxiliaries For Economic Benefit And Demand Side Management

Abstract

dc:description

This thesis describes a novel system that is being developed that utilizes latent thermal energy storage (LTES) to shift residential heating and cooling loads, between 2-4 hr. time periods, away from the electrical power grid (during the utilities’ peak demand period) for the main purpose of residential demand-side-management. More and more utilities are now offering residential time-of-day rates (and load interrupt programs) to help improve their load factor as a means to curtail the building of new power generating stations, and will only increase in time with greater implementation and the enabling use of smart meters.TES is ideally suited to capitalize on this fact and stands ready in this proposed new system; running the HVAC equipment during the time of excess system capacity and storing the “hot or cold energy created” in the PCM for later use during the peak system demand period will improve the system’s load. This thesis describes the proposed system and the equipment layout along with its operating strategy. In addition to being modular in design and thus allowing for all different size homes, another major key feature of the proposed system is that it is of the “plug-in” type which utilizes the current cooling and heating hardware of the existing home, and as such, is equally applicable to new home construction or retrofits. This thesis also presents the economics of the system and potential benefits to the home owner, more specifically, simple calculations are given showing the estimated monthly operating cost savings when using this TES system with residential time-of-day (TD) rates, over that of the home operating without TES and running on the standard residential service (RS) rate structure.This thesis document provides the detailed mathematical formulation for the solution of planar moving boundary problems using enhanced enthalpy method with given fixed temperature and insulated boundary conditions. The solution methodology and results, obtained using numerical solution, are presented and described thoroughly in this document. Additionally, numerical solution’s convergence, grid sensitivity analysis and MATLAB code validation have been presented in this document.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Mechanical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yaser, Hussnain A.
Chair dc:contributor.committeechair
  • Kazmierczak, Michael

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Yaser, Hussnain A.. Novel System Design For Residential Heating And Cooling Load Shift Using PCM Filled Plate Heat Exchanger And Auxiliaries For Economic Benefit And Demand Side Management. masters thesis, University of Cincinnati, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1397234246