University of Cincinnati
A Non-invasive Prototype Device for Detecting Intracerebral Hemorrhage
Abstract
dc:descriptionIntracerebral hemorrhage (ICH) causes 67,000 deaths per year with the total volume of blood being the best predictor of outcome. Therefore, it is important to detect the ICH as early as possible to minimize damage to the brain. Often, the patient will have symptoms, which will allow the physician to determine if there is a hemorrhage by obtaining a computed tomography (CT) scan of the brain. Yet, the progression of the hematoma is unknown without getting another CT. After bleeding has occurred, the ICH causes perihematomal edema (PE), a secondary injury that causes further deficits in the patient. Even though most patients suffering from an ICH show symptoms, comatose or sedated patients do not, so it is difficult to know what their neurological status is at any given time. Therefore, there is a clinical need for a real-time, non-invasive device that can monitor the neurological status of a patient at any given time. A device using radiofrequency (RF) electromagnetic radiation has been developed that can detect hemorrhage and PE in an in vivo porcine model. This device is limited because it can only detect relative changes from an initial measurement. In this dissertation, the progress of this device is discussed, from a stationary dual-antennae setup that can detect changes due to the presence of ICH to the development of a mobile antennae system, which allows for RF antennae to be moved and monitor for changes throughout the brain. A brain-mimicking gelatin model, which simulates the electrical properties of the human brain, was developed for in vitro experimentation. Cavities of different volumes and geometrical configurations of blood were placed in the gel to simulate an ICH, and blood volumes as small as 1 mL could be detected. From these results, a qualitative model for detecting ICH was developed and discussed in relation to the experimental data. Different frequencies were studied, and it has been found that 950 MHz is an optimal frequency for detecting changes due to ICH and PE in an in vivo porcine ICH model. By moving the antennae around the head in a grid pattern, the different grid locations could be compared to each other, and there is potential to use these comparisons to determine if ICH and PE are present without requiring baseline measurements. Overall, there has been significant development in determining the optimal antennae characteristics necessary for developing an array of antennae that can monitor a patient for changes due to an ICH.
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Medicine: Neuroscience/Medical Science Scholars Interdisciplinary
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Korfhagen, Joseph J.
- Chair dc:contributor.committeechair
-
- Danzer, Steve
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- unrestricted
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier