Back to search

University of Cincinnati

Spatial Dosimetry with Violet Diode Laser-Induced Fluorescence of Water-Equivalent Radio-Fluorogenic Gels

Abstract

dc:description

The following work describes investigations of spatial dosimetry using laser-induced fluorescence of a radio-fluorogenic detector embedded within water-equivalent media. The chemical composition of a gelatin-based coumarin-3-carboxylic acid detector was investigated and dose response characterized. Violet diode (405nm) excitation sources were explored and laser-induced fluorescence (LIF) employed to obtain the pattern of fluorescent emission yielding images of the integrated spatial dose distribution. The design of a three-dimensional reader is proposed to provide a foundation for future work. Radio-fluorogenic processes create fluorescent products in response to ionizing radiation. Water radiolysis produced by ionizing radiation yields hydroxyl free radicals that readily hydroxylate coumarin-3-carboxylic acid to 7-hydroxy-coumarin-3-carboxylic acid, a derivative of umbelliferone. Umbelliferone is a known fluorophore, exhibiting peak excitation in the UV to near UV range of 365-405nm with a visible 445nm blue emission. Coumarin-3-carboxlyic acid has been studied in an aqueous gelatin matrix. The radio-fluorogenic coumarin-gelatin detector has been shown to respond to an absorbed dose of ionizing radiation in a measureable manner. The detector was studied with respect to concentration of gelatin and coumarin in the presence of pH buffers. Dose response of the detector was investigated with regard to ionizing radiation type, energy, and rate of irradiation. Results demonstrate a functional detector.Patterns of energy deposition were formed in response to ionizing radiation produced by a sealed-source of radioactive Ir-192 embedded in the gelatin matrix of the detector. Spatial distributions of absorbed dose were recorded and analyzed as a function of fluorescent emission. The distribution of energy deposition was imaged with LIF excitation by a divergent beam of 405nm light and determined by analysis of digital image pixel intensity values displaying the 445nm fluorescent emission. Results demonstrate spatial dosimetry proof of principle.A basic dedicated reader system was fabricated employing LIF. Images of fluorescent emission excitation profiles were obtained in multiple aqueous samples and processed to obtain a dose response. Design of an optical reader system for the radio-fluorogenic detector is explained and a three-dimensional dosimetry system proposed. Three-dimensional imaging principles with LIF have been illuminated.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering and Applied Science: Nuclear and Radiological Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sandwall, Peter A., II
Contributors dc:contributor
  • Spitz, Henry

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Sandwall, Peter A., II. Spatial Dosimetry with Violet Diode Laser-Induced Fluorescence of Water-Equivalent Radio-Fluorogenic Gels. doctoral thesis, University of Cincinnati, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1397477646