Back to search

University of Cincinnati

Effects of hemodynamic stresses on the remodeling parameters in arteriovenous fistula

Abstract

dc:description

Failure of arteriovenous fistula (AVF) due to formation of stenosis is one of the major causes of morbidity among dialysis patients. Hemodynamic parameters are believed to play a crucial role in the remodeling and functionality of the AVFs. Our central hypothesis is that wall shear stress (WSS), flow, and pressure can be used to predict the remodeling behavior and thus, the functionality of AVFs over time. To test this hypothesis, three specific aims are formulated:1) To assess the longitudinal effects of WSS on the changes in luminal area and intima-media thickening (IMT) of AVFs in a pig model.2) To evaluate the longitudinal effects of local WSS on the corresponding changes in the luminal area and IMT using an improved experimental setup. 3) To determine the variation of two new diagnostic endpoints for better assessment of the functionality status of AVFs over time.Methodology and primary results of the above three specific aims are presented below:Specific aim 1: 6 AVFs were created between the femoral arteries and veins of 3 pigs, each pig having two AVFs on either limb. The AVFs were divided into two groups:1) curved AVFs (C-AVF) and 2) straight AVFs (S-AVF). The WSS and luminal area were calculated at 2D (D: days), 7D, and 28D post-surgery. The amount of IMT was measured at 7D (2 AVFs) and 28D (4 AVFs). The slope of changes in WSS between successive time points (t') was also calculated and correlated with the changes in luminal area/diameter and IMT. For the C-AVFs, t' was negative, i.e. WSS decreased over time. The negative t' for the C-AVFs was associated with luminal dilation and outward hypertrophy of the venous wall (favorable remodeling). For the S-AVF, t' was positive, i.e. WSS increased over time. The positive t' for the S-AVFs was associated with luminal constriction and inward hypertrophy and, subsequently, venous stenosis. Thus, t' can provide important information on the remodeling behavior of AVFs. Specific aim 2: Under an improved experimental setup, 12 AVFs were created in 6 pigs. However, only 6 AVFs (3 pigs), out of 12, were used in our analysis. All the new techniques were successfully implemented on these 6 AVFs. These AVFs were monitored at 4 post-surgery time points: 2D, 7D, 14D, and 28D. The t' was found to have a significant inverse correlation with the changes in luminal area over time. This finding reconfirmed our conclusions from specific aim 1. In order to evaluate the effects of local flow characteristics on the remodeling behavior of AVFs, the geometry of fistulas were divided into four major segments: anastomosis, first and second bend of the S-shaped segment, and outflow. The minimum area, maximum WSS, and largest IMT were found in the first and second bend of the S-shaped segment of the AVFs. The flow field of these bends was dominated by the formation of in-plane vortices and an asymmetric velocity field. Therefore, these findings suggested a possible linkage between the flow characteristics and the higher likelihood of stenosis formation in the first and second bend of S-shaped segment as compared to the other regions.Specific aim 3: The 6 AVFs in specific aim 1 were used to calculate two new functional diagnostic parameters: 1) the non-linear pressure drop coefficient (Cp: pressure drop normalized by dynamic pressure at proximal artery) and 2) the linear resistance index (R: pressure drop scaled by velocity at proximal artery). Also, the scaled values of Cp and R, denoted as Cp* and R*, were calculated using the scaled velocity by the curvature ratio of the anastomosis segment at proximal artery. These parameters were able to combine the hemodynamic and anatomical effects into one single endpoint. Cp and R were able to distinguish between the favorable and adverse remodeling parameters in AVFs, and thus, they could be promising endpoints to diagnose the functionality of AVFs over time.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering and Applied Science: Mechanical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rajabi Jaghargh, Ehsan
Chair dc:contributor.committeechair
  • Banerjee, Rupak

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Rajabi Jaghargh, Ehsan. Effects of hemodynamic stresses on the remodeling parameters in arteriovenous fistula. doctoral thesis, University of Cincinnati, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1427962400