Back to search

University of Cincinnati

Ultraharmonic and Broadband Cavitation Thresholds for Ultrasound Contrast Agents in an In-Vitro Flow Model

Abstract

dc:description

Ultrasound-enhanced thrombolysis (UET) is under development as an adjuvant to thrombolytic administration for the treatment of ischemic stroke. Initial studies have demonstrated the efficacy of UET in the presence of ultrasound contrast agents (UCAs), stabilized microbubbles that can be injected into the bloodstream. These studies demonstrated ultrasound-enhanced thrombolysis when acoustic emissions characteristic of stable cavitation, ultraharmonics (UH) and the subharmonic (SH), were present. The current study was performed to determine the threshold for cavitation activity in an in- vitro human clot model in flow exposed to an UCA and 120-kHz pulsed or continuous wave ultrasound. Two UCAs were used to nucleate cavitation, Definity® and echogenic liposomes (ELIP). Definity® is a commercially available UCA, and ELIP are potential theragnostic agents for the treatment of stroke, with the potential to encapsulate and release drugs, such as the thrombolytic drug recombinant tissue-plasminogen activator (rt-PA), upon exposure to ultrasound. UH and broadband (BB) cavitation thresholds occurred at the same acoustic pressure (0.3 ± 0.1 MPa, peak-to-peak) for both UCAs, and were mostly independent of the ultrasound duty cycle.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Biomedical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gruber, Matthew J.
Chair dc:contributor.committeechair
  • Holland, Christy

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Gruber, Matthew J.. Ultraharmonic and Broadband Cavitation Thresholds for Ultrasound Contrast Agents in an In-Vitro Flow Model. masters thesis, University of Cincinnati, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428066108