Back to search

University of Cincinnati

Thermal Ablation Monitoring Using Ultrasound Echo Decorrelation Imaging

Abstract

dc:description

<p>Hepatocellular carcinoma (HCC) and colorectal metastases (CRC) are common tumors worldwide with an increasing incidence in the United States. Thermal ablation techniques such as radiofrequency ablation (RFA), high intensity focused ultrasound (HIFU), microwave and laser ablation techniques have shown potential to treat unresectable tumors. Still lacking is a treatment monitoring technique that can accurately predict ablation. Echo decorrelation imaging is a novel pulse-echo ultrasound imaging method that quantifies and maps changes in echo signals occurring over millisecond time scales during thermal ablation. </p><p>In this dissertation, the utility of echo decorrelation imaging as a treatment monitoring tool was assessed during <i> in vivo </i> and <i> in vitro </i> thermal ablation. To test the utility of echo decorrelation imaging for the prediction of ablation, RFA was performed on <i> ex vivo </i> bovine liver (<i>N</i> = 9). Echo decorrelation was computed from the Hilbert transformed pulse-echo data acquired during RFA treatments. For comparison, integrated backscatter was also computed from the same data. Pixel-by-pixel comparison between the echo decorrelation and integrated backscatter maps and the ablated region from gross tissue histology was performed using receiver operating characteristic (ROC) curves. Echo decorrelation and integrated backscatter were then quantitatively evaluated as predictors of ablation. The area under the ROC curves (AUROC) was determined for both echo decorrelation and integrated backscatter imaging methods. Ablation was predicted more accurately with echo decorrelation (AUROC = 0.820) than with integrated backscatter (AUROC = 0.668). </p><p> To test the utility of echo decorrelation imaging for the prediction of ablation during <i>in vivo</i> thermal ablation, RFA was performed on normal swine liver (<i>N</i> = 5) and ultrasound ablation using image-ablate arrays was performed on rabbit liver implanted with VX2 tumors (<i>N</i> = 2). Consistent with the <i> in vitro </i> studies, ablation was predicted more accurately with echo decorrelation (AUROC = 0.833 and 0.776 for RFA and ultrasound ablation, respectively) than with integrated backscatter (AUROC = 0.733 and 0.494). </p><p>Mean cumulative echo decorrelation was greater in the ablated tissue regions compared to the unablated regions for both <i>in vitro</i> (<i>t</i> = 6.808, <i>p</i> = 6.10<sup>-6</sup>, <i>N</i> = 9) and <i>in vivo</i> (<i>t</i> = 3.498, <i>p</i> = 0.036, <i>N</i> = 5 ) RFA treatments, indicating the ability of echo decorrelation to delineate between the ablated and unablated regions. For <i>in vivo</i> RFA, motion gating reduced the mean echo decorrelation in both ablated (<i>t</i> = 3.526, <i>p</i> = 0.036, <i>N</i> = 5) and unablated (<i>t</i> = 5.173, <i>p</i> = 0.013, <i>N</i> = 5) regions. However, with or without motion gating, the mean cumulative echo decorrelation was significantly greater in the ablated region than in the unablated region (<i>t</i> = 3.883, <i>p</i> = 0.008, <i>N</i> = 5).</p><p>The effect of tissue temperature on echo decorrelation was assessed during <i>in vitro</i> RFA. RFA experiments (<i>N</i> = 15) were performed on <i>ex vivo</i> bovine liver tissue. Temperature maps were simulated by a finite element method, with tissue parameters determined using an unscented Kalman filter to best match measured ablation results. Significantly higher AUROC values (<i>p</i> = 0.019, <i>p</i> ≤ 10<sup>-14</sup>, <i>p</i> ≤ 10<sup>-14</sup>) were obtained for the prediction of tissue temperatures greater than 40, 60, and 80 °C with echo decorrelation (AUROC = 0.871, 0.948, and 0.966) when compared to integrated backscatter (AUROC = 0.865, 0.877, and 0.832). Overall, the results presented in this dissertation show potential for the utility of echo decorrelation imaging as a treatment monitoring tool.</p>

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Engineering and Applied Science: Biomedical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Subramanian, Swetha
Contributors dc:contributor
  • Mast, T. Douglas

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Subramanian, Swetha. Thermal Ablation Monitoring Using Ultrasound Echo Decorrelation Imaging. doctoral thesis, University of Cincinnati, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428068754