Echo Decorrelation Imaging of In Vivo HIFU and Bulk Ultrasound Ablation

Abstract

dc:description

Echo decorrelation imaging, a pulse–echo method that maps heat-induced changes in ultrasound echoes, was investigated for <i>in vivo</i> monitoring of thermal ablation in a liver cancer model. In open surgical procedures, rabbit liver with implanted VX2 tumor were imaged by image-ablate arrays and treated with bulk ultrasound (unfocused) ablation (<i>N</i>=10) or high-intensity focused ultrasound (HIFU) (<i>N</i>=13). Echo decorrelation and integrated backscatter (IBS) images were formed from pulse-echo images recorded during rest periods following each sonication pulse. Echo decorrelation images were corrected for motion- and noise-induced artifacts using measured echo decorrelation from corresponding sham trials. Sectioned ablated tissue was vitally stained with triphenyl tetrazolium chloride (TTC) and binary images were constructed based on local TTC staining. Analysis was performed for the focused exposures, unfocused exposures and for all exposures combined. <p>Motion correction significantly reduced echo decorrelation in non-ablated liver regions. The reduction was significant in non-ablated VX2 tumor regions for focused exposures and all exposures combined. The reduction was not significant in ablated VX2 tumor regions for unfocused exposures. Echo decorrelation reduction was marginally significant in ablated regions for focused and unfocused exposures and was significant for all exposures combined.<p>Prediction of ablation by echo decorrelation and IBS imaging was assessed using receiver operating characteristic (ROC) curves. Areas under the ROC curve (AUC) were significantly greater than chance for ablated liver prediction by corrected echo decorrelation and IBS. Echo decorrelation did not predict ablated VX2 tumor significantly better than chance for focused exposures. IBS did not predict ablated VX2 tumor better than chance for focused exposures and unfocused exposures. Corrected echo decorrelation predicted ablated liver significantly better than IBS for the focused exposures and all exposures combined. AUC differences between corrected echo decorrelation and IBS were not significant for all exposure groups in ablated VX2 tumor, for which echo decorrelation was marginally higher. At the optimal threshold, defined as the threshold corresponding to the point nearest to the top left-hand corner of the ROC plot, echo decorrelation had a better sensitivity than specificity for the focused and unfocused exposures in normal liver and VX2 tumor. <p>To assess tissue motion effects due to large inter-frame times, echo decorrelation and IBS was computed for inter-frame times up to 847.5 ms. Uncorrected and corrected echo decorrelation prediction performance was marginally affected by large inter-frame times; however, corrected decorrelation was less affected. IBS prediction performance was nearly constant by comparison for large inter-frame times. Over the range of inter-frame times investigated, IBS predicted overall better than echo decorrelation for the unfocused group while echo decorrelation predicted overall better than IBS for the focused group. <p>These results indicate echo decorrelation imaging is a successful predictor of local ablation, with potential for successful clinical implementation.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Biomedical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fosnight, Tyler R.
Chair dc:contributor.committeechair
  • Mast, T. Douglas

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Fosnight, Tyler R.. Echo Decorrelation Imaging of In Vivo HIFU and Bulk Ultrasound Ablation. masters thesis, University of Cincinnati, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1447691239