Back to search

University of Cincinnati

Uptake and Exposure Measurements in Health Physics Technicians Associated with 131I-MIBG Patient Therapy

Abstract

dc:description

<sup>131</sup> I-metaiodobenzylguanidine, <sup>131</sup> I-MIBG, has increasingly been used as an effective radiotherapeutic agent for pediatric patients diagnosed with neuroblastoma. While not a cure, the agent allows patients the possibility of controlling their disease and lengthening disease stabilization. Radioiodine pharmaceuticals were reformulated in 1979 to reduce exposure to those attending to the patient by reducing the volatility of the iodine and increasing the use of encapsulation to limit the quantity of unbound radioiodine. However, therapeutic <sup>131</sup> I-MIBG may still be administered to the patient through a liquid form. Health physics technicians are responsible for ensuring regulatory compliance and safety in and around the patient’s room. This study was performed to determine if the health physics technicians were exposed to<sup> 131</sup> I while performing required tasks within the patient’s treatment room. Results showed that per therapeutic treatment, the health physics technicians were exposed to an average of 6.9x10<sup>-1</sup> µSv hr<sup>-1</sup>GBq. Furthermore, trace contaminate levels of <sup>131</sup> I were detected by direct, in vivo measurement in persons having a normal and hypoactive thyroid. In vivo measurements were performed using a single 2900 mm <sup>2</sup> high resolution germanium detector positioned approximately 3 cm from the thyroid while the subject was seated in a shielded room. The thyroid activity measured in the technicians was well below requirements for monitoring established by the U.S. Nuclear Regulatory Commission. Established methods and working conditions are adequate to insure that radiation exposure to health physics technicians supporting the<sup> 131</sup> I-MIBG radioiodine therapeutic procedures are consistent with the program to keep exposure as low as reasonably achievable.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Mechanical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Collier, Jason L.
Contributors dc:contributor
  • Spitz, Henry

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Collier, Jason L.. Uptake and Exposure Measurements in Health Physics Technicians Associated with 131I-MIBG Patient Therapy. masters thesis, University of Cincinnati, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1460729902