Back to search

University of Cincinnati

The Impact of Humidity on an Optical Chemical Sensing Device for Non-invasive Exhaled Gas Monitoring

Abstract

dc:description

A novel technique for the detection of acetone in human breath was previously developed as a non-invasive medical diagnostic tool for potential use in the monitoring blood glucose level of diabetic patients. Perfluorosulfonic acid (PSA) polymer membrane, commercially available as Nafion® 117, was used as the heterogeneous catalyst for the condensation reaction of ambient acetone and imbibed immobilized resorcinol reagent. The condensation reaction product, a flavan compound, yielded a unique colorimetric response, which can be measured over time using UV/VIS spectroscopy. Previous studies have shown that by introducing a weak organic acid such as tiglic acid into the membrane prior to exposure, it is possible to preserve the catalytic activity of the PSA groups. An increase in light absorbance due to the reaction was observed in the presence of 100% relative humidity as the concentration of the tiglic acid imbibed increased. This was the first time this colorimetric response was shown to provide comparable light absorption under both ambient humidity and 100% relative humidity condition.The focus of the research described this thesis was to develop an optical sensing device for real time detection in practical clinical applications. An in-situ flow cell was used in this work to determine whether the condensation reaction was able to provide a rapid response during acetone exposure. Using the flow cell system, dynamic response of different concentration of tiglic acid imbibed membrane exposure to both ambient humidity and 100% relative humidity was determined. The dynamic response obtained in this research confirmed that acid based membrane was able to provide us a signal within 100 seconds under both dry and wet condition. The results suggested that the acid based membrane can be used in uncontrollable humidity environment such as human breath but only in the kinetic-controlled region of acetone transport into the membrane.As part of this work, evaluation and optimization of a bench-top prototype was conducted to evaluate the effects of temperature, flow rate and pre and post humidification of both membrane and sample chamber. A strong linear correlation of the optical signal from the device was observed at a given exposure to acetone at early times as long as steady humidification in the sample chamber was maintained. Steady humidification was inferred from the strong influence of flow rate (which affected pressure), temperature, and sample chamber pre-conditioning. A small group of clinical trials were conducted assess the prototype response under real-world conditions. As in the case of constant acetone exposure, linear correlation (typically, R2>0.9) was observed between the optical response and exposure at early times. Consistent with previous work that suggested correlation of breath acetone and blood glucose, we observed a linear correlation between the slope of the optical response and breath acetone concentrations and blood glucose concentrations for diabetics. Such excellent correlations motivate further research on uses of this device to assess the exhaled breath composition for various disease biomarkers.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Chemical Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Qian, Zexin
Contributors dc:contributor
  • Angelopoulos, Anastasios

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Qian, Zexin. The Impact of Humidity on an Optical Chemical Sensing Device for Non-invasive Exhaled Gas Monitoring. masters thesis, University of Cincinnati, 2016. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1471347710