Back to search

University of Cincinnati

Multi-fidelity Design and Analysis of Single Hub Multi-rotor High Pressure Centrifugal Compressor

Abstract

dc:description

Centrifugal compressors are favorable because they can generate high pressure ratio due to large change in radius from inlet to exit of compressor. This increase in trend to achieve high pressure ratios with increase blade loading narrows stable operating range of centrifugal compressor with stall and surge at relatively higher mass flow rate. Present research was aimed to improve the stall mass flow rate of centrifugal compressor. A novel configuration is designed and analyzed to overcome this issue by placing multiple rotors on the same hub with a vane in between similar to a multi-stage axial compressor blade arrangement. It is designed in such a way that the flow from the first row is adjusted by the stator for optimum performance of second blade row. A 0D tool has been developed for multi-rotor impellers to provide an estimate of work ratio. Work done by compressor is adjusted between the two blade rows to achieve optimum performance. A mean-line design code (CIMdes) is developed to study the effect of stator inlet flow angles on pressure ratio, work done, overall pressure ratio, isentropic efficiency and diffusion factor. Performance parameters were studied on a 1.5 stage impeller having a blade length of approximately one-third of the total blade length for each blade row using CIMdes. Numerical simulations are carried out through steady CFD analysis at design and off-design conditions for 100% speed-line to understand the flow physics in the compressor. Grid sensitivity study is conducted for three grids with 0.38, 1.9 million and 2.8 million elements respectively. The results obtained are validated with DLR centrifugal compressor. Stall mass flow rate is 18.6% lower than single-rotor compressor. Loss quantification revealed that diffuser losses are higher in single-stage and the novel design increased the backsweep angle resulting in lower diffuser losses. The flow capacity is extended near the stall with a penalty in efficiency. The preliminary analysis demonstrate the advantages of the multi-staging on the same hub and extends the design space for performance range improvement with some trade-offs.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering and Applied Science: Aerospace Engineering
Grantor dc:publisher
University of Cincinnati
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Muppana, Sai
Chair dc:contributor.committeechair
  • Abdallah, Shaaban

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Muppana, Sai. Multi-fidelity Design and Analysis of Single Hub Multi-rotor High Pressure Centrifugal Compressor. masters thesis, University of Cincinnati, 2018. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1553517075653458