Back to search

University of Cincinnati

DEVELOPMENT OF IMMUNOMAGNETIC BEAD ASSAY WITH ELECTROCHEMICAL DETECTION FOR USE IN A MINIATURIZED SENSOR

Abstract

dc:description

A bead based enzyme immunoassay for the model antigen mouse IgG has been developed with rotating disk electrode (RDE) detection. Alkaline phosphatase was used as the enzyme label to convert substrate 4-aminophenyl phosphate to the electroactive 4-aminophenol (PAP). The detection scheme allows enzyme turnover to be monitored continuously and thus reduces errors associated with obtaining data at fixed times as in flow injection analysis. The determination of PAP by the RDE has a linear range from 5 x 10 <sup>-9</sup> to 5 x 10 <sup>-5</sup> M. An 800 µl electrochemical cell was used to minimize enzyme product dilution. A linear response, for mouse IgG was obtained in this non-optimized system over the concentration range of 50 to 5000 ng/ml. The third chapter describes an immunoassay with dendrimer-modified 2.8 µm magnetic beads for the artificial microorganism, Bugbead. Bugbead consists of a 0.39 µm diameter polystyrene bead coated with proteins via avidin-biotin binding to represent the epitopes on a real microorganism. Starburst© PAMAM dendrimer (G 0.5, G 2.5, G 5.5) was covalently attached to the beads and capture antibody was attached to dendrimer termini by means of the avidin-biotin binding. The effect of dendrimer on the immunoassay was evaluated by comparison to an assay with commercial streptavidin beads to which the same capture antibody was bound. RDE amperometry in a micro drop was used to continuously monitor the enzyme turnover. The antibody bound/bead increases with the dendrimer generation used. With G 5.5 beads there is an improvement in assay sensitivity over the range of analyte concentrations studied. Beads with G 2.5 had assay sensitivity similar to the streptavidin beads and the beads with G 0.5 had poorer sensitivity. Different surface modifications and ion-pair agents were also studied in an attempt to reduce non-specific signal. The assay for ovalbumin was developed using a streptavidin bead based sandwich immunoassay coupled to electrochemical detection using the RDE in a small volume to minimize product dilution and improve detection limits. The assay developed has a detection limit of 0.1 ng/ml. Assay sensitivity in complex matrices such as food and serum was also evaluated.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Purushothama, Shobha
Contributors dc:contributor
  • Heineman, William

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • restricted--full text not available online
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Purushothama, Shobha. DEVELOPMENT OF IMMUNOMAGNETIC BEAD ASSAY WITH ELECTROCHEMICAL DETECTION FOR USE IN A MINIATURIZED SENSOR. doctoral thesis, University of Cincinnati, 2001. http://rave.ohiolink.edu/etdc/view?acc_num=ucin984589640