Back to search

University of Cincinnati

RAPID MICROIMMUNOASSAY WITH ELECTROCHEMICAL DETECTION

Abstract

dc:description

Three types of electrochemical sandwich microimmunoassays have been developed using paramagnetic microbeads for the heterogeneous surface and mouse IgG for the model analyte. In all three, the enzyme label alkaline phosphatase (ALP) was used to convert the substrate 4-aminophenyl phosphate (PAPP) into the electroactive product 4-aminophenol (PAP). The assay incubations were carried out in microwells with earth magnets used to separate the beads from the supernatant during rinses. Since adapting the detection schemes widely used in electrochemical immunoassay (i.e., FIA-EC and LC-EC) proved difficult for bead-based assays, three new detection schemes were developed. In the first method, a rotating disk electrode (RDE) was applied on a microdrop of PAPP to which the beads were added for detection. Direct analysis in a microdrop minimizes the PAP dilution, a key requirement in achieving very low detection limits. Furthermore, the detection scheme allowed enzyme turnover to be monitored continuously, thus shortening the detection time and reducing the errors associated with obtaining data at fixed times as in FIA-EC. A non-optimized calibration curve for mouse IgG was obtained from 50 to 5000 ng/mL with detection times of less than a minute. In the second method, scanning electrochemical microscopy (SECM) was used to detect the electroactive product generated over microspots of beads. This approach was first demonstrated with beads coated with mouse IgG-ALP conjugates. Detection was carried out in the SECM generation-collection mode by oxidizing PAP formed over the microspots. The signal height correlated with the amount of beads present in the microspot. Next, the SECM feedback mode was used to image streptavidin-coated beads that were labeled with biotinylated glucose oxidase. Finally, working with microspots with a top-view radius of 75 microns, a miniaturized sandwich assay was carried out, and a detection limit of 1.5 x 10 <sup>-15</sup> moles of mouse IgG was obtained. In the third method, meso-scale microfluidic systems were used to carry out completely automated assays in approximately 30 minutes. These assays yielded a calibration curve for mouse IgG in the range of 50 - 1000 ng/mL.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Arts and Sciences : Chemistry
Grantor dc:publisher
University of Cincinnati
Year dc:date
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wijayawardhana, Charles Ajith
Advisor dc:contributor.advisor
  • Heineman, William

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • restricted--full text not available online
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Wijayawardhana, Charles Ajith. RAPID MICROIMMUNOASSAY WITH ELECTROCHEMICAL DETECTION. doctoral thesis, University of Cincinnati, 2001. http://rave.ohiolink.edu/etdc/view?acc_num=ucin991310119