Back to search

University of Cincinnati

A NEW DYNAMIC CULTURE SYSTEM DESIGNED TO PROVIDE CONTROLLED STRAIN TO CELL SEEDED COLLAGEN CONSTRUCTS FOR TENDON REPAIR

Abstract

dc:description

The primary objective of this study was to develop and characterize a mechanical strain system that is capable of providing precise, controlled strain to cell seed collagen constructs in vitro. In addition, the viability of the cells in the constructs formed in the wells of the culture dish was evaluated to verify that the cells survive extended periods in culture. Finally, the strain on the surface of the constructs was briefly investigated to estimate the strain that the constructs experience for given displacements of the ends of the culture dish. The purpose of developing this system was to test the hypothesis that mechanical strain will improve the structure, biochemistry, and/or biomechanics of the tissue engineered construct. The system houses silicone culture dishes that sustain cell seeded collagen constructs for extended periods of time in vitro. The system consists of 5 pneumatic strain devices that each hold one culture dish, a junction box, a control panel, and a computer interface that controls the strain profile. Each silicone culture dish contains four wells with two vertical posts around which the cell-seeded collagen constructs contract. The pneumatic strain system controls the peak strain, frequency, and duty cycle of the dishes. There is a linear relationship between the displacement of the dish end and the percent strain between the vertical posts in the wells of the dish. The percent strain is dependant upon the location of the wells in the strain apparatus. Strain in the wells nearest the drive end is, on average, 0.30% more than at the stationary end. Autoclaving dishes significantly decreases the post-to-post strain in the wells, but a period of extended cycling (100,000 cycles, 0.5 Hz) at 1.9 mm end-to-end displacement removes the effect. Viability studies indicate that cells survive the preparation and contraction process and are still viable up to 28 days in culture. Surface strain studies indicate that strain is highest near the ends and lowest in the mid section. The middle two-thirds, on average, experiences only 70% of the applied post-to-post percent strain, while the ends experience up to 160% of the applied post-to-post strain

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Engineering : Engineering Mechanics
Grantor dc:publisher
University of Cincinnati
Year dc:date
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • SCHANTZ, ERIC J.
Advisor dc:contributor.advisor
  • Butler, Dr. David L.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • restricted--full text not available online
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

SCHANTZ, ERIC J.. A NEW DYNAMIC CULTURE SYSTEM DESIGNED TO PROVIDE CONTROLLED STRAIN TO CELL SEEDED COLLAGEN CONSTRUCTS FOR TENDON REPAIR. masters thesis, University of Cincinnati, 2001. http://rave.ohiolink.edu/etdc/view?acc_num=ucin992533611