University of Cincinnati
Imposed Work of Breathing and Breathing Comfort of Nonintubated Volunters Breathing with Three Portable Ventilators and a Critical Care Ventilator
Abstract
dc:descriptionIn spontaneous breathing modes, past laboratory work using a lung model indicated portable ventilators as compared to critical care ventilators may increase inspiratory work of breathing. The purpose of this study was to assess the imposed inspiratory work of breathing and breathing comfort of nonintubated healthy volunteers breathing spontaneously through three portable ventilators and a critical care ventilator in a controlled environment. A physiologic theoretical framework was used for the study. With all subjects having continuous positive airway pressure (CPAP) settings of 0 and 5 cm H<sub>2</sub>O and pressure support ventilation (PSV) settings of 0 and 10 cm H<sub>2</sub>O, the hypotheses were: 1) Imposed work (WOB<sub>I</sub>) and pressure-time product (PTP<sub>I</sub>) with the 7200ae (Mallinckrodt, critical care ventilator) will be less than those in the Achieva (Mallinckrodt) ventilator and LTV 1000 (Pulmonetic) ventilator, which will be less than those of the Univent 754 (Impact) ventilator (WOB<sub>I</sub> and PTP<sub>I</sub> with 7200ae < Achieva = LTV 1000 < Univent 754); 2) breathing comfort (BC) reported by subjects breathing with the 7200ae will be greater than that with the Achieva and LTV 1000, which will be greater than the Univent 754 (BC with 7200ae > Achieva = LTV 1000 > Univent 754). The study used a randomized, single blind repeated measures design using healthy nonobese subjects (n=16). Measured respiratory parameters were saved to a personal computer and subjects recorded BC on a visual analogue scale that had been previously assessed for validity. Control breathing periods were interposed after each fourth study period; maximum inspiratory pressure was the proxy measure for fatigue. Baseline airway pressure was determined in real-time and retrospectively with the differences compared for each ventilator and control period. Repeated measures ANOVA was used to analyze the data with α < 0.05. There were no significant differences in the measures during the control breathing periods or in baseline airway pressures. The ventilator was a source of significance for WOB<sub>I</sub>, PTP<sub>I</sub>, and BC (p < 0.0001). Tukey's method for comparison of means revealed the WOBI, PTPI were greater and BC of subjects was less with the Univent 754. Although the data did not fully support the research hypotheses, the WOB<sub>I</sub>, PTP<sub>I</sub>, and BC were significantly different in the Univent 754. The other portable ventilators offered no significant increase in WOB<sub>I</sub>, and PTP<sub>I</sub> nor decrease in BC compared to the critical care ventilator. The differences seen with the Univent 754 were likely due its triggering method, constant inspiratory flow, and intrinsic positive end-expiratory pressure. Further clinical studies are warranted.
Degree
thesis:*- Name thesis:degree_name
- PhD
- Level thesis:degree_level
- doctoral
- Discipline thesis:degree_discipline
- Nursing : Doctoral Program in Nursing
- Grantor dc:publisher
- University of Cincinnati
- Year dc:date
- 2001
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Austin, Paul Nelson
- Advisor dc:contributor.advisor
-
- Sommers, Marilyn
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- restricted--full text not available online
- This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- http://rave.ohiolink.edu/etdc/view?acc_num=ucin997382634