Back to search

Wright State University

Comparison of Two Methods of External Scatter Dose Contributions to the Contralateral Breast

Abstract

dc:description

<p>The treatment outcomes of many forms of breast cancer have become very favorable. The usual standard of successful treatment of five years without a recurrence is not adequate any longer for breast cancer. Many patients live well beyond this time interval only to have a second malignancy develop in the contralateral breast ten or twenty years later. Boice et al (1992) found that there was a correlation between the amount of dose to the contralateral breast and the likelihood of a secondary malignancy forming. </p><p>The normal practice today is to use multi-leaf collimators (MLC) to modulate the photon beam in radiation therapy. Due to the limited use of physical compensators, very little data has been presented as to their effectiveness in reducing dose to the contralateral breast. This study will use a Varian 2100 C/D linear accelerator to irradiate a Rando phantom with simulated breast material using both the traditional method and the compensator method. The dose to the contralateral breast will be measured using MOSFETs at various depths in the tissue. </p><p>The results suggest that the compensators do not reduce the dose to the contralateral breast as effectively as the MLC method. There were a few instances for specific cases where the compensator performed better and these cases require further study for verification and clarity.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Wright State University
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Cutlip, James
Contributors dc:contributor
  • Foy, Brent

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • unrestricted
  • This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws.
Language dc:language
English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
OhioLINK
Base URL
etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Cutlip, James. Comparison of Two Methods of External Scatter Dose Contributions to the Contralateral Breast. masters thesis, Wright State University, 2008. http://rave.ohiolink.edu/etdc/view?acc_num=wright1215567494